4. PROCEDURES DE PURGE, TEST DE CONTROLE DES FUITES ET ESSAI DE FONCTIONNEMENT
4-1. PROCEDURES DE PURGE ET TEST DE CONTROLE DES FUITES
5HWLUH] OH ERXFKRQ GH O¶RXYHUWXUH GH VHUYLFH GX URELQHW G¶DUUrW GX F{Wp GX FRQGXLW GH JD]
GH O¶XQLWp H[WHUQH $ O¶RULJLQH OHV URELQHWV G¶DUUrW VRQW FRPSOqWHPHQW IHUPpV HW UHFRXYHUWV
G¶XQ FDSXFKRQ
5DFFRUGH] OD YDQQH GX FROOHFWHXU j MDXJH HW OD SRPSH j YLGH j O¶RXYHUWXUH GH VHUYLFH GX
URELQHW G¶DUUrW GX F{Wp GX FRQGXLW GH JD] GH O¶XQLWp H[WHUQH
%RXFKRQ GX
*4 à 5 tours
URELQHW G¶DUUrW
&RXSOH GH
)HUPHU
à 29,4 N•m, 200
*Ouvrir
j NJIFP
Clé hexagonale
%RXFKRQ GH O¶RXYHU-
ture de service
&RXSOH GH j
17,7 N•m, 140 à
NJIFP
Précautions à prendre lors de l'utilisation de la vanne de commande
5!
A
Ouvrir
Corps
1¶RXEOLH] SDV GH
)HUPHU
Vanne de
replacer le bouchon
commande
DSUqV O¶RSpUDWLRQ
0HWWH] OD SRPSH j YLGH HQ PDUFKH )DLWHV OH YLGH MXVTX¶j REWHQWLRQ GH PLFURQV
&RQWU{OH] OD GpSUHVVLRQ DLQVL REWHQXH DYHF OD YDQQH GX FROOHFWHXU j MDXJH SXLV IHUPH]
OD YDQQH HW DUUrWH] OD SRPSH j YLGH
3DWLHQWH] SHQGDQW XQH PLQXWH RX GHX[ $VVXUH]YRXV TXH O¶DLJXLOOH GH OD YDQQH GX
FROOHFWHXU j MDXJH UHVWH GDQV OD PrPH SRVLWLRQ 9pUL¿H] TXH OH PDQRPqWUH LQGLTXH XQH
SUHVVLRQ GH ± 03D >-DXJH@ ± PP+J
5HWLUH] UDSLGHPHQW OD YDQQH GX FROOHFWHXU j MDXJH GH O¶RXYHUWXUH GH VHUYLFH GX URELQHW G¶DUUrW
AVERTISSEMENT
3RXU pYLWHU WRXW ULVTXH G¶LQFHQGLH DVVXUH]YRXV TX¶DXFXQH VXEVWDQFH LQÀDP-
PDEOH Q¶HVW SUpVHQWH RX TX¶LO Q¶H[LVWH DXFXQ ULVTXH G¶LQÀDPPDWLRQ DYDQW
d'ouvrir les robinets d'arrêt.
/RUVTXH OHV FRQGXLWHV GH UpIULJpUDQW VRQW UDFFRUGpHV HW SXUJpHV RXYUH] FRPSOqWHPHQW
OHV URELQHWV G¶DUUrW DX[ GHX[ H[WUpPLWpV GHV FRQGXLWV GH OLTXLGH HW GH JD] /D PLVH HQ
VHUYLFH VDQV RXYULU FRPSOqWHPHQW OHV URELQHWV G¶DUUrW GLPLQXH OH UHQGHPHQW GH O¶XQLWp HW
SHXW rWUH VRXUFH GH SDQQH
5HSRUWH]YRXV DX[ pWDSHV HW FKDUJH] OD TXDQWLWp GH UpIULJpUDQW UHFRPPDQGpH VL
QpFHVVDLUH 9HLOOH] j FKDUJHU OHQWHPHQW OH OLTXLGH UpIULJpUDQW 6LQRQ OD FRPSRVLWLRQ GH
UpIULJpUDQW GDQV OH V\VWqPH SHXW FKDQJHU HW DIIHFWHU OHV SHUIRUPDQFHV GX FOLPDWLVHXU
6HUUH] OH ERXFKRQ GH O¶RXYHUWXUH GH VHUYLFH SRXU UHFUpHU OHV FRQGLWLRQV G¶RULJLQH
7HVW GH FRQWU{OH GHV IXLWHV
0DQRPqWUH FRPELQp SRXU OH
± 03D
PRGqOH 5 5$
± PP+J
0DQRPqWUH
SRXU OH PRGqOH 5 5$
5RELQHW G¶DUUrW
SRXU /,48,'(
Vanne du collecteur à jauge
SRXU OH PRGqOH 5 5$
Poignée
basse
Poignée haute
7X\DX GH FKDUJH SRXU OH
5RELQHW G¶DUUrW
PRGqOH 5 5$
pour GAZ
Adaptateur
DQWLUHÀX[
3RPSH j YLGH RX SRPSH j
vide équipée d'une fonction
DQWLUHÀX[
/RUVTXH YRXV ¿[H] OD YDnne de commande à
l'ouverture de service, le noyau de vanne peut
se déformer ou se relâcher en cas de pression
excessive &HOD SHXW HQWUDvQHU XQH IXLWH GH JD]
/RUVTXH YRXV ¿[H] OD YDQQH GH FRPPDQGH
Ouverture
j O¶RXYHUWXUH GH VHUYLFH YHLOOH] j FH TXH OH
de service
noyau de vanne soit en position fermée,
SXLV VHUUH] OD SDUWLH $ 1H VHUUH] SDV OD
SDUWLH $ RX QH WRXUQH] SDV OH FRUSV ORUVTXH
Tuyau de
charge
OH QR\DX GH YDQQH HVW HQ SRVLWLRQ RXYHUWH
(66$, '( )21&7,211(0(17
,QVpUH] OD ¿FKH G¶DOLPHQWDWLRQ pOHFWULTXH GDQV OD SULVH VHFWHXU HW
RX HQFOHQFKH] OH GLVMRQFWHXU
$SSX\H] XQH IRLV VXU O¶LQWHUUXSWHXU GH VHFRXUV (2 6: SRXU OH
5()52,',66(0(17 &22/ HW GHX[ IRLV SRXU OH &+$8))$*(
+($7 /¶HVVDL GH IRQFWLRQQHPHQW YD V¶HIIHFWXHU SHQGDQW PLQXWHV
Si l'ampoule supérieure du témoin de fonctionnement clignote toutes
OHV VHFRQGHV YpUL¿H] OH FkEOH GH FRQQH[LRQ GH O¶XQLWp LQWHUQH
H[WHUQH $ SRXU GpWHFWHU WRXW PDXYDLV EUDQFKHPHQW /H PRGH
G¶XUJHQFH WHPSpUDWXUH UpJOpH VXU & SUHQGUD OH UHODLV j OD ¿Q GH
O¶HVVDL GH IRQFWLRQQHPHQW
3RXU DUUrWHU OH IRQFWLRQQHPHQW DSSX\H] SOXVLHXUV IRLV VXU OH ERXWRQ
(2 6: MXVTX¶j FH TXH OHV WpPRLQV /(' V¶pWHLJQHQW &RQVXOWH] OD
QRWLFH G¶XWLOLVDWLRQ SRXU SOXV G¶LQIRUPDWLRQV
&RQWU{OH GH OD UpFHSWLRQ GHV VLJQDX[ LQIUDURXJHV GH OD WpOpFRPPDQGH
$SSX\H] VXU OD WRXFKH $55(70$5&+( GH OD WpOpFRPPDQGH
HW YpUL¿H] O¶DXGLELOLWp GX VLJQDO VRQRUH pOHFWURQLTXH SURYHQDQW
GH O¶XQLWp LQWHUQH $SSX\H] GH QRXYHDX VXU OD WRXFKH $55(7
0$5&+( GH OD WpOpFRPPDQGH SRXU pWHLQGUH OH FOLPDWLVHXU
$ O¶DUUrW GX FRPSUHVVHXU OH GLVSRVLWLI GH SUpYHQWLRQ GX UHGp-
marrage se met en marche pour éviter le redémarrage du com-
SUHVVHXU SHQGDQW PLQXWHV SRXU SURWpJHU OH FOLPDWLVHXU
4-3. FONCTION DE REDEMARRAGE AUTOMATIQUE
&H SURGXLW HVW pTXLSp G¶XQH IRQFWLRQ GH UHGpPDUUDJH DXWRPDWLTXH /RUVTXH O¶DOLPHQWDWLRQ
VH FRXSH SHQGDQW OH IRQFWLRQQHPHQW FRPPH ORUV GHV SDQQHV G¶pOHFWULFLWp OD IRQFWLRQ
remet automatiquement l'unité en marche sur le réglage précédent dès que l'alimentation
HVW UpWDEOLH &RQVXOWH] OD QRWLFH G¶XWLOLVDWLRQ SRXU SOXV G¶LQIRUPDWLRQV
Precaution :
$SUqV O¶HVVDL GH IRQFWLRQQHPHQW RX OH FRQWU{OH GH OD UpFHSWLRQ GHV VLJQDX[ GH OD
WpOpFRPPDQGH pWHLJQH] O¶XQLWp j O¶DLGH GX ERXWRQ (2 6: RX GH OD WpOpFRPPDQGH
DYDQW GH FRXSHU O¶DOLPHQWDWLRQ 6LQRQ O¶XQLWp VH UHPHWWUD DXWRPDWLTXHPHQW HQ PDUFKH
ORUVTXH O¶DOLPHQWDWLRQ HVW UpWDEOLH
A l'attention de l'utilisateur
$SUqV LQVWDOODWLRQ GH O¶XQLWp YHLOOH] j H[SOLTXHU j O¶XWLOLVDWHXU OD IRQFWLRQ GH UHGpPDUUDJH
DXWRPDWLTXH
6L OD IRQFWLRQ GH UHGpPDUUDJH DXWRPDWLTXH Q¶HVW SDV LQGLVSHQVDEOH HOOH SHXW rWUH
GpVDFWLYpH $GUHVVH]YRXV DX UHVSRQVDEOH GH O¶HQWUHWLHQ SRXU GpVDFWLYHU OD IRQFWLRQ
&RQVXOWH] OH PDQXHO G¶HQWUHWLHQ SRXU SOXV G¶LQIRUPDWLRQV
4-4. EXPLICATIONS DESTINEES A L'UTILISATEUR
$ O¶DLGH GH OD 127,&( '¶87,/,6$7,21 H[SOLTXH] j O¶XWLOLVDWHXU O¶HPSORL GX FOLPDWLVHXU
XWLOLVDWLRQ GH OD WpOpFRPPDQGH UHPSODFHPHQW GHV ¿OWUHV j DLU QHWWR\DJH SUpFDXWLRQV
j SUHQGUH SRXU OH IRQFWLRQQHPHQW HWF
5HFRPPDQGH] j O¶XWLOLVDWHXU GH OLUH DWWHQWLYHPHQW OD 127,&( '¶87,/,6$7,21
lnterrupteur de
VHFRXUV (2 6: