Using The Marmitek X-10 System With Multiple Phases; Technical Information - Marmitek IR455 B&O to X-10 converter Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

XM10
Visit www.marmitek.com for more information:
www.marmitek.com/in-wall: for built-in switches and Micromodules
www.marmitek.com/plug-in: for plug-in modules, screw-in modules etc.
7. USING THE MARMITEK X-10 SYSTEM WITH MULTIPLE
PHASES
In some houses the energy supply is not 1x 230V, but 3x 230V. This is called a 3-phase
system. In these cases, it can be necessary to couple these phases for the Marmitek X-10
signals. You can couple the phases by using FD10 phase coupling filters (art. nr. 08934). You
need to do this when your wall sockets and light points are divided over multiple phases.
Multiple groups do not pose any problems when using the Marmitek X-10 signal. For larger
buildings we advise using an active 3-phase amplifier (CAT3000, art. nr. 09304) instead of
phase coupling filters.
More information on X-10 signals and your mains can be found on:
www.marmitek.com/X10signal

8. TECHNICAL INFORMATION

Infrared reception frequency:
Infrared range:
Dimensions:
Power:
X-10 command set:
X-10 Collision detection:
IR455
455kHz
max. 10 meter. When the infrared signal has been converted
to X-10, the signal range is extended to the entire house.
105x105x30mm
12V AC/DC 350mA
Standard X-10 (ON, OFF, DIM, BRIGHT, ALL LIGHTS ON, ALL
UNITS OFF) and Extended X-10 (directly calling up the
dim values: is supported by dimmer modules with a
memory function)
Present
MARMITEK X-10 modules
11

Publicité

Table des Matières
loading