Before
charging
While
charging
Charge
indicator
lamp
(RED /
BLUE /
Charging
GREEN /
complete
PURPLE)
Overheat
standby
Charging
impossible
(2)
Regarding the temperature of the rechargeable
battery.
The temperatures for rechargeable batteries
are as shown in the Table 3, and batteries that
have become hot should be cooled for a while
before being recharged.
Rechargeable
batteries
BSL36B18
(3) Regarding recharging time (At 68°F (20°C))
Table 4 Charging time
Charger
Battery
BSL36B18
12
Indications of the charge indicator lamp
Lights for 0.5 seconds. Does not
Blinks
light for 0.5 seconds. (off for 0.5
(RED)
seconds)
Lights for 0.5 seconds. Does not
Blinks
light for 1 second. (off for 1 second) Battery capacity at less than
(BLUE)
Lights for 1 second. Does not
Blinks
light for 0.5 seconds. (off for 0.5
(BLUE)
seconds)
Lights
Lights continuously
(BLUE)
Lights continuously
Lights
(GREEN)
(Continuous buzzer sound: about
6 seconds)
Lights for 0.3 seconds. Does not
Blinks
light for 0.3 seconds. (off for 0.3
(RED)
seconds)
Lights for 0.1 seconds. Does not
light for 0.1 seconds. (off for 0.1
Flickers
seconds)
(PURPLE)
(Intermittent buzzer sound: about
2 seconds)
Table 3
Temperatures at which the
battery can be recharged
32°F – 122°F
(0°C – 50°C)
UC18YSL3
Approx. 52 min.
Table 2
NOTE
The recharging time may vary according to the
ambient temperature.
4.
Disconnect
receptacle.
CAUTION
Do not pull the plug out of the receptacle
by pulling on the cord.
Make sure to grasp the plug when removing
from receptacle to avoid damaging cord.
5.
Remove the battery from the battery charger.
Supporting the battery charger with hand, pull
out the battery from the battery charger.
NOTE
Be sure to pull out the battery from the battery
charger after use, and then keep it.
Plugged into power source
50%
Battery capacity at less than
80%
Battery capacity at more
than 80%
Battery overheated. Unable
to charge. (Charging will
commence when battery
cools)
Malfunction in the battery or
the charger
battery