Wireless flush-mount actuator with switch wiring 868.3 MHz

Function

The wireless flush-mount actuator with switch wiring is part of the
Brennenstuhl Home Automation Systems BrematicPRO, controlled via
app or the BrematicPRO PC software. The wireless flush-mount actuator
with switch wiring can be connected and controlled directly with the
BrematicPRO wireless remote control. It can be directly linked with
the Brennenstuhl Home Automation Systems BrematicPRO via the
BrematicPRO Gateway to use other software-based functions (e.g.
timer control, theme control, astro function).
For information on which components are compatible with the
wireless flush-mount actuator with switch wiring, please visit:
www.brematic.com/en/service.
For additional information on components, please refer to the
instructions for use of the respective BrematicPRO wireless component.

Installation

Note: Check before installation whether the product is located within
the range of the Gateway.
CAUTION! DANGER OF ELECTRIC SHOCK!
Only install the device in a de-energised state! Disconnect the
electrical mains supply line by switching off the circuit breakers
connected to it or unscrewing the fuse. Prevent this from being
unintentionally re-started e.g. with a warning sign.
Before installation, check the mains supply line with a suitable
measuring device to see that it is de-energised.
The mains voltage on site must correspond with the technical
data of the device (see "Technical data").
Check the power input of the consumer you intend to connect
to the device prior to installation.
The maximum load is approx. 400 W.
The device must be operated in a suitable flush-mounted box or
surface mount box or assembled in another suitable casing to
guarantee the necessary electric shock protection.
Only operate the device when it is stationary.
ATTENTION! Risk of short circuit for switch
connection! Insulate the cable ends of the braid pair to
prevent short circuits.
12 EN
L
N
PE
Connect the supply voltage cable to the screw terminals L and N
(N = neutral conductor, L = phase) (see Fig.).
Connect the consumer to the both of the centre screw terminals
(see Fig.).
For consumers with a PE / ground conductor connection, the
ground conductor must be connected.
An external potential-free switch (no button) can be connected
to the multi-wire cable. In addition, the wireless actuator can be
switched on or off via the external switch.
The multi-wire cables are insulated with insulating sleeves in their
delivery state. Remove the insulating sleeves, i.e. using a knife,
before connecting an external switch to the multi-wire cables.
Ensure during installation that the pair button on the housing
front is not covered and that it is not pressed by accident.

Download app / PC software BrematicPRO

The Brennenstuhl Home Automation Systems BrematicPRO is controlled
via the BrematicPRO app / PC software. The app can be downloaded
for free from the App Store and Google Play. The PC software is available
for download at www.brematic.com/en/service.
Please follow the on-screen instructions for download and installation.
For more information about the app and how to use it, please visit
www.brematic.com/en/service.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Smarthome brematic pro

Table des Matières