Information about Wireless Operation
This device uses the 868.3 MHz proprietary wireless protocol. Wireless
transmission is implemented using a non-exclusive channel, interference
can therefore not be excluded.
The range in buildings may vary greatly from open areas. In addition to
the transmission power and the reception characteristics of the receivers,
ambient conditions, e.g. humidity in addition to the structural conditions
on site, are important factors.
The range can be significantly reduced in part due to:
• wood, gypsum, concrete, reinforced concrete walls
• proximity to metal and conductive objects
• broadband interference, e.g. in residential areas (DECT phones,
mobiles, wireless headphones, wireless speakers, wireless
weather stations, baby monitors)
• proximity to electric motors, transformers, mains adapters, computers
Duty Cycle
Duty cycle refers to a transmission time limit regulated by law for
devices transmitting in the 868 MHz range. It is intended to ensure
smooth operation of devices operating in the 868 MHz range. The
maximum transmission time of each device is 1 % of an hour
(corresponding to 36 seconds / hour). Once the 1 % limit has been
reached it cannot transmit until the time limit of the duty cycle has
ended, so after one hour.
Included in delivery
1 x Wireless flush-mount actuator with switch wiring
1 x Quick start guide
1 x Instructions for use (digital, available for download)
Technical data
Product designation:
UPMS 868 01 W400 3726
Item no.:
1294710
Radio frequency:
868.3 MHz
Frequency:
868.1 - 868.5 MHz
Max. transmitting power: < 20 mW
Duty cycle:
< 1 % per h
Supply voltage:
230 V/AC, 50 Hz
Max. switching capacity: 400 W
Power input:
1.3 W
Ambient temperature:
0 °C to 35 °C
Protection type:
IP00
Open area range:
approx. 100 m
Wireless flush-mount actuator with switch wiring 868.3 MHz
Dimensions (W x H x D): 52 x 49.5 x 16.9 mm
Weight:
Subject to technical changes without notice.
Device overview
Front
Connections
L External conductor
connection L 230 V phase
(input)
N Neutral conductor
connection N 230 V
(consumer)
30 g
Pair button
Device LED
Stranded wires to
connect to switch
(no button)
Switched external conductor
L 230 V phase (consumer)
N Neutral conductor connection
N 230 V (input)