FRIMEDA TPA-R
Checking of connection fi ttings
As with all load-carrying devices, ring
clutches must be checked at least
once a year by a qualifi ed expert to
ensure safe operation.
There is no defi ned maximum work-
ing life for FRIMEDA Ring clutches.
Clutch head TPA-R1/R2/R3
The ring clutch has to be decommissioned
if the clutch head has been deformed or
the mouth opening is enlarged; this can
not be repaired. Refer to the table for
allowable wear tolerances.
Replacing the locking bolt on ring
clutches
Ring clutches with worn or bent lock-
ing bolts must be decommissioned.
Refer to the table for allowable wear
tolerances.
2
TPA-R1 Shackle
Clutches with visible signs of damage
or excessive wear must be decommis-
sioned immediately. Refer to the table
for allowable wear tolerances.
TPA-R2/R3
Wire cables
Wire cables should be checked for
the following defects:
• kinking and buckling
• any broken braid
• signs of corrosion
• slackening of the outermost
exposed layer in free length
• crushing in free lengths
• crushing in the loop with more
than 4 ruptured wires for braided
© 2015 HALFEN · INST_TPA-R 08/15 · www.halfen.com
Users are expressly warned against
using our products with products of
other manufacturers.
The correct function and safety of the
ring clutches can only be guaranteed
when using original FRIMEDA Ring
cables, or more than 10 ruptured
wires for cable-laid rope
• damage or severe wear to the
d
s
cable connector or cable-end
connector
• high number or ruptured wires
Checking the wire cables has to
include looking for signs of slipping
between the cable and the ferrule.
Wire cables must be kept away
from any aggressive material to avoid
corrosion; acids, alkaline fl uids etc.
Crane hooks must have a large radius.
Sharp-edged hooks or hooks with
small cross section, and therefore
small radii, can lead to unacceptable
damage of the wire cables.
clutches with FRIMEDA Anchors.
When checking FRIMEDA Ring clut-
ches, the following points must be
observed:
Load
group
1,25
e
10,0
26,0
Load
group
1,25
10,0
26,0
Load
group
10,0
26,0
f
As the clutch head usually has a
longer service life than the wire loop,
clutch heads with worn wire cables
can be replaced by HALFEN.
Decommission wire cables immediately
if the following numbers of ruptured
wire cables are visible:
Cable
Braided
cable
Assembly Instructions
Nominal dimension
e [mm]
7.0
±0.12
2,5
12.0
±0.5
5,0
18.0
+0.5/−1.0
22.0
±0.5
34.0
+2.0/−1.0
Nominal dimension
d
[mm]
2
8.0
+0.4/−0.6
2,5
13.0
+0.7/−0.4
5,0
16.5
+0.7/−0.4
23.5
+0.8/−0.4
32.0
+0.9/−0.5
Nominal dimension
f [mm]
2,5
14 ± 0.4
5,0
20 ± 0.6
26 ± 0.8
40 ± 1.0
No. of visible ruptured
wires over a length of
type
3d
6d
S
S
4
6
Max. e
[mm]
8
14
20
24
38
Min. d
2
[mm]
7
12
15
22
30.5
Min. f
[mm]
12.5
18.5
24
38.0
30d
S
16
5