A c c e s s o r i e s
S t e m D e f l e c t o r
The stem deflector is a very simple alternative to the standard stem collector and allows access in restricted areas. To replace the
stem collector with the stem deflector proceed as follows:
Preparing the Base Tool for use with Stem Deflector
The air line must be disconnected before any servicing or dismantling.
'Sealed Nut' 71213-02200 replaces Locknut 39 (to cut-off air supply to Vacuum System) as follows:
•
Loosen Locknut 39 using
16mm AF Spanner.
•
Unscrew and remove both
Male 'T' Adaptor 40 and
Locknut 39.
•
Replace Locknut 39 with
'Sealed Nut' 71213-02200,
screw 'Sealed Nut' onto Head
Piston 35 to disable Vacuum
System.
•
Male 'T' Adaptor 40 must be
tightened onto Head Piston
35, finally tightening 'Sealed
Nut' against it.
•
Remove the Stop Plate
Assembly (page 24) by
unscrewing Screws 63 (2off).
•
Fit Stem Deflector (07340-00342) into Adaptor (71213-20101).
•
Push the assembled Stem Deflector and Adaptor over Bottle
Adaptor Assembly 31 and align with the cut-out feature.
E x t e n s i o n
Fitted between the tool and the nose assembly the extension allows
access into deep channels.
•
The Tool must be fitted with Jaw Spreader Housing 9* (71210-
02101) and 'O' Ring before extension (71210-20300). See
page 11.
•
To fit the extension, remove any nose assembly components.
•
Screw the Inner extension to Jaw Spreader Housing 9*.
•
Screw the Outer extension onto Head Assembly 50.
•
Fit the nose assembly onto the extension.
Item numbers in bold refer to the general assembly drawing and parts list on pages 26 and 27.
9* refers to illustrations on pages 11 and 12.
39
ADAPTOR
71213-20101
INNER
EXTENSION - NON QUICK RELEASE 71210-20300
71213-20101
ADAPTOR
STEM DEFLECTOR
07340-00342
STEM DEFLECTOR: 71213-20100
EXTENSION - 'T' ADAPTOR 71213-12000
07340-00342
STEM DEFLECTOR
SEALED NUT
71213-02200
OUTER
13