Installing LED module
conversion in the
light fitting eLL. 92
Before installation the LED module shall be
inspected for any transport damage (cracks
or other damage to the LED module) to
ensure its good order and condition.
The warning labels on the LED module
shall be observed.
1.Open eLL. 92 light fitting in accordance
with the operating instructions for the light
fitting (Fig. 3.1).
2.Remove the fluorescent tubes (Fig. 3.2).
3.Open the reflector flaps at each end
(Fig. 3.3).
4.Remove the plastic-light-switch-cover
(Fig 3.4).
5.Replace the old plastic-light-switch-cover
with the new EMC-light-switch-cover
(Fig. 3.5 and Fig. 3.7).
6.Fit the EMC contact (Fig. 3.6) into the
reflector. Ensure that the mounting position
is correct. (Figs. 3.8 and 3.9).
Do not squeeze the connection
cables!
All connection cables shall be fitted with
great care to ensure that they are not
damaged when the reflector flap or the
light fitting is closed.
7.Connect the terminal of the EMC contact to
the EMC light switch cover in the given
position (Fig. 3.10)
8.Connect the connection cable of the EMC
light switch cover to the PE terminal of the
light fittin. (Fig. 3.11).
9.Align the LED module so that the EMC pin
of the LED module engages in the EMC
contact socket of the light fitting. Snap the
module into the G13 sockets of the light
fitting, whereby a distinct clicking sound
can be heard (Fig. 3.12).
10.Close the light fitting (Fig 3.13).
The type of protection of the light fitting is
extended to include the type of protection of
the LED module.
8 8 8 8 8
Cooper Crouse-Hinds GmbH
LED module 400 / LED module 800
6.1
Installing LED module in light
fitting eLL. 92 with
EMC-equipment
The light fitting eLL. 92 is has already been
equipped with EMC-light-switch-cover (Fig.
3.5) and EMC contact (Fig. 3.6).
Before installation the LED module shall be
inspected for any transport damage (cracks
or other damage to the LED module) to
ensure its good order and condition.
The warning labels on the LED module
shall be observed.
1.Open eLL. 92 light fitting in accordance
with the operating instructions for the light
fitting (Fig. 3.1).
2.Remove the fluorescent tubes (Fig. 3.2).
3.Align the LED module so that the EMC pin
of the LED module engages in the EMC
contact socket of the light fitting. Snap the
module into the G13 sockets of the light
fitting, whereby a distinct clicking sound
can be heard (Fig. 3.12).
4. Close the light fitting (Fig 3.13).
6.2
Reinstallation of conventional
fluorescent tubes in light fittings
If the eLL. 92 light fitting is to be used with
conventional fluorescent tubes again, the
following shall be observed:
1.Open the eLL. 92 light fitting in accordance
with the operating instructions for the light
fitting.
2.Remove the LED module
(Fig. 3.14 and Fig. 3.15).
3.Fit the fluorescent tubes into the G13
sockets of the light fitting. Here it is
necessary to observe the operating
instructions for the light fitting.
6.3

Taking into operation

For further "taking into operation" observe
the relevant remarks of the operating
instruction of the light fitting.
7

Maintenance/Servicing

Observe the national regulations
applicable to the maintenance, servicing
and test of electrical apparatus as well as
the general rules of engineering
(e.g. IEC/EN 60079-17)!
Check that there is no voltage or take
suitable protective measures.
Only original COOPER CROUSE-HINDS
GMBH parts shall be used for carrying out
repairs.
The required maintenance intervals are
set according to their application and
should therefore be determined
depending on the conditions of use.
When servicing the apparatus, particularly
those parts that are decisive for the type of
protection against explosion, will have to be
checked.
If during servicing repairs prove to be
necessary, section 8 of these operating
instructions will have to be observed.
8
Repairs / Overhaul
In the event of damage, replacement of
these components is mandatory. In case
of doubt, the respective apparatus shall
be sent to Cooper Crouse-Hinds / CEAG
for repair.
Alterations or modifications to the LED
module are not permitted.
9
Disposal/Recycling
When the LED module is disposed of, the
respective national regulations on waste
disposal will have to be observed.