PROBLEM
WHAT HAPPENS
The shredder
- The ENERGY SMART Optical
fails to start
Illuminated Indicator (3) does
not come on.
The Stand-by light (1) does
not come on.
- The red light (2) comes on.
- The ENERGY SMART Optical
Illuminated Indicator (3) and
Stand-by light (1) come on.
- When paper is inserted into
the throat the machine fails
to start;
The shredder
- Optical Illuminated Indicator
never stops
(3) on, cutting blades
operating.
Significant
- Capacity reduced compared
reduction of
with capacity when cutting
shredding
blades are oiled.
capacity
Red light (2) flashing.
Compliant with
- LVD Directive (2014/35/UE)
- RoHS Directive (2011/65/EU )
- CEM Directive (2014/30/UE)
The manufacturer
ELCOMAN SRL
VIA GORIZIA,9
Declares herewith that the following paper shredders comply with the standards of the LVD Directive 2014/35/UE
- KOBRA series: Kobra 400
Standards applied are :
EN 60950-1 :2006/A11 :2009/A1 2010/A12 :2011
EN 55014-1 :2006
EN 55014-2 :1997+A1 :2001
EN 61000-3-2 :2006
Bovisio Masciago, 15.01.2020
A.DE ROSA
T
O
EchnicAl
fficE
TROUBLESHOOTING
CAUSE
- Button position (G)
- Lid (A) not closed properly.
- Bag full (E).
- Motor in heat protection
mode.
- Cable not connected properly.
- No electrical power.
Material and/or dirt deposited
on photo cells (5) or (5a).
- Oil in container (P) has run
out.

DECLARATION OF CONFORMITY

20813 BOVISIO MASCIAGO (MB) – ITALY-
EN 61000-3-3 :1995 + A1(2001) + A2(2005)
EN 61000-4-2 (1995) + A1(1998) + A2(2001)
EN 61000-4-3 (2006)
EN 61000-4-4 (2004)
11
ACTION
- Turn button to " I " position.
-Close the lid properly.
- Empty the bag.
- Wait 15 minutes for motor to cool
down.
- Check if machine is plugged in
correctly to power socket.
- Check if the socket is switched on.
Remove deposit from photo cells.
- Replace oil container (P).
EN 61000-4-5 (2006)
EN 61000-4-6 (2007)
EN 61000-4-8 (1993) + A1 (2001)
EN 61000-4-11 (2004)