Danfoss RAVL ring
1 Place the RAVL ring around the valve of the radiator.
It needs not to be bolted on.
2 Pull out the fixing ring until a 'CLICK' is heard.
3 Push the product onto the radiator.
4 Fasten the fixing ring by turning it clockwise.
The product is now mounted to the radiator.
5 Press the OK button.
The valve actuation turns out from the product. 'AdA' appears on the display.
When properly mounted the home screen appears on the display. With an incorrect assembly,
an error code (F1, F2 or F3) appears. See chapter 'Failure' for more information.
6.4 Reinstallation of the smart thermostat head
Perform the following steps to reinstall the thermostat head, without erasing the memory:
1 Keep the Menu button pressed until 'Pro' appears on the display.
2 Choose 'INS' by turning the dial button.
3 Press the OK button.
The valve turns in and out of the product to find the proper adjustment. 'AdA' appears on
the display.
7 Operation
7.1 Manual operation of the heating control set
7.1.1
View the current temperature
1 Turn the dial button until the desired temperature is shown on the display.
2 On the home screen, press repeatedly on the Menu button until 'Manu' appears.
The manual temperature setting now applies.
7.1.2
De actuele temperatuur bekijken
1 Keep the Menu button pressed until 'Pro' appears on the display.
2 Choose 'tEP' by turning the dial button.
24 User maual –wireless climate control
E
F
D
E
D
E