E - Special features
COUNTING ZONE
Site configuration.
-Click on the "Site" menu and select
the "Modify" submenu.
- Click on the icon "Counting Zone" .
- Enter the number of zones you wish to add
(Maximum from 1 to 8 zone).
Configuration of the readers with Counting function.
- Click on the "Reader" menu and select
the "configure" submenu
- Select a Reader from the droplist
- In the «Anti Passback» section, select a zone
for that reader.
- Set the reader as Entry or Exit.
- Enable the function Counting, click on the red
square next to counting. When it turns
green then the function is ON.
- Click on «SAVE»
- Click on «EXIT »
Configuration of a Zone.
- The zone can be renamed (maximum 16 characters)
in "Area name".
- Capacity: Enter the number of places
- Used places: Enter the number of places already
taken in the zone. This would be done if the area
is not empty at the time of programming the system.
- Threshold: Enter the number of places that would
indicate a Parking status Not Full.
e.g. if the capacity of the parking is 250 cars then indicate a threshold
at 240 to avoid a continuous status modification «full/not full» every
time a car or a person will enter and exit the place.
> SELECT THE PARkING STATUS FULL YES OR NO (Y, N).
> CLICk ON «VALIDATE» > CLICk ON «SAVE» > CLICk ON «EXIT »