Restarting The System - Ten Haaft SamySolar Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Restarting the system

As with any other computer-controlled device, it is possible for the software in
your SamYSolar+® system to "crash". This may be caused by external infl uences, for
example strong electromagnetic interference, or previously undetected software
errors.
E
If you think that your SamYSolar+® system is responding incorrectly or it is not res-
ponding at all, then we recommend restarting the microprocessor. This can be done
in two different ways and in any state of the system:
If the fuse in the wiring harness is easily accessible, remove the fuse and then insert
it in its holder again after a few seconds.
If the fuse is not accessible, disconnect the Western connector on the right-hand
side of the control panel. To do this, press the plastic clip from behind against the
body of the Western connector and then pull the connector out from the unit. Next,
press the two buttons
and
on the control panel, keep them pressed and plug
the Western connector back in again. Now you can let go of the two buttons.
In both of the cases described above your SamYSolar+® system will perform an
internal restart. If the system is unfolded, it is retracted straight away. After the
restart the system is in rest mode and can be started in the usual way using the
key.
80