TECHNICAL FEATURES

Ta=25° C unless otherwise specified.
Mains side
Description
Supply Voltage
Frequency
Absorbed Maximum Current
Power Factor
Absorbed Maximum Power
Battery side
Description
Output current ripple
Absorbed current
Output voltage ripple
Maximum power supplied
Output capacity
General
Description
Operating range of temperature
Maximum relative humidity
Switching frequency
Efficiency
Maximum size
Weight
Enclosure class
Protection and Safety
Description
Insulation
Insulation
Insulation
Leakage current
Input fuse
Output fuse
Minimum output voltage of operation (Battery
Detector)
Reverse output polarity
Thermal protection of semiconductors
(Temperature of Thermal Alarm)
Safety Requirements (Rules)
EMC Requirements (Rules)
This device is in conformity with the Low Voltage directive 2006/95/CE and EMC
directive 2004/108/CE and their further modifications.
8
Battery charger BC1
Symbol
Test Condition
Vin
f
Iin max
P = P max
P = P max
cosϕ
Pin max
P = P max
Symbol
Test Condition
-
I = I1
I a
Equipment turned off
-
U = U1
P max
U = U1, I = I1
C
Symbol
Test Condition
∆T
RH
f c
At each condition
η
a×b×c
Without connecting cable
-
Without connecting cable
-
Symbol
Test Condition
-
Mains to Battery side
-
Mains side to Earth
-
Battery side to Earth
I L
Supplied equipment
F1
Inside the equipment
F2
Inside the equipment
-
Equipment turn on
-
At the connection to the Battery
-
Ta=55° C
-
EN60335-1, EN60335-2-29
-
EN55014-1, EN61000-3-3
EN55014-2, EN61000-4-2
EN61000-4-4, EN61000-4-5
EN61000-4-6, EN61000-4-11
Value and/or Range
-
230 ± 10%
-
Value and/or Range
-
Value and/or Range
-
from -20 to +50
-
-
286×106×77
-
Value and/or Range
10 (delayed)
Protection provided
by fuse F2
Unit
Veff
50 ÷ 60
Hz
5
Aeff
0,7
-
850
W
Unit
< 5%
-
< 1
mA
< 1%
-
720
W
1000
µF
Unit
° C
90%
-
80 ± 5%
kHz
> 85%
-
mm
1390
g
IP20
-
Unit
1250
V
AC
500
V
DC
500
V
DC
< 3
mA
A
40
A
1,3
V/cell
-
100
° C
-
-
-
-
D01001-10