Induction Generator Fault Indicator - Salvis Compactline Série Mode D'emploi

Masquer les pouces Voir aussi pour Compactline Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

en
Fault
Empty cooking
hob switches on.
Small metallic ob­
jects are heated.
After switching on,
the fuses blow.
If you cannot remedy the fault,
‒ switch off the appliance and disconnect from the mains,
‒ do not open the housing,
‒ contact the authorised Customer Service agent.
7.1

Induction generator fault indicator

Example fault No. 4 - number of flashing
signals
long
1
The flashes must be counted. The number of flashes indicates the error code. The error can be de­
termined from the table below.
Number of
flashes
--
1
2
3
4
28 / 64
Possible cause
Pot detection incorrect
Generator defective
2 3
4
long
1
Fault
Cause
No fault
No fault
No power being
Unsuitable pan material
generated
No coil current, hard­
ware overcurrent
Coil or power PCB
faulty
No power being
Unsuitable pan material
generated
High coil current, soft­
ware overcurrent
CPU or power board
faulty
The appliance
Temperature on heat
switches off.
sink too high.
Fan, rectifier, sensor or
CPU faulty.
The appliance
Hob temperature - over­
switches off.
heating
Sensor faulty.
Action
Contact an authorized customer service.
Contact an authorized customer service.
Fault message display
‒ The indicator light illuminates for approx. 0.6
seconds.
2 3
4
‒ This is followed by rapid flashing signals.
Action
Compare with different hob and cook­
ware.
Notify an authorized customer service
agent if the problem occurs again
with other induction cookware.
Compare with different hob and cook­
ware.
Notify an authorized customer service
agent if the problem occurs again
with other induction cookware.
Clean air filter.
Have the supply and exhaust air
checked by an authorized customer
service agent and have the fan
cleaned.
Have the components checked by an
authorized customer service.
Empty cookware
Cookware damaged by overheating
and no longer usable.
Contact the authorized Customer
Service if the fault recurs.

Publicité

Table des Matières
loading

Table des Matières