Télécharger Imprimer la page

AKG Acoustics CK 69-ULS Mode D'emploi page 6

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Specifications
(measureed with C 480 B preamplifier)
Type:
Frequency range:
Sensitivity at 1000 Hz
Plar pattern:
Impedance:
Recommended load impedance:
Equivalent noise level to DIN 45 405
(CCIR 468-2)
Equivalent noise level to DIN 45 412
(A weighted)
Signal/noise ratio re 1 Pa (A weighted)
Max. SPL for 0.5 % THD
**) re 1 V/Pa
**) into recommended load impedance
Combined pressure gradient/interference microphone
20 to 18.000 Hz ± 2 dB from specified curve
0 dB position:
27 mV/Pa
+6 dB position:
54 mV/Pa
-10 dB position:
8.5 mV/Pa
Directional
≤150 Ω
2000 Ω // 1 nF (IEC 268 15 A)
0 dB position:
16 dB
+6 dB position:
20 dB
-10 dB position:
25 dB
0 dB position:
9 dB-A
+6 dB position:
11 dB-A
-10 dB position:
15 dB-A
0 dB position:
85 dB
+6 dB position:
83 dB
-10 dB position:
79 dB
0 dB position:
200 Pa
+6 dB position:
100 Pa
-10 dB position:
250 Pa
-31 dBV*)
-25 dBV*)
-41 dBV*)
140 dB SPL**)
134 dB SPL**)
142 dB SPL**)

Publicité