Cleaning and maintenance
What To Do If......
Problem
The appliance does not
work.
The Led on the knob
blinks.
The appliance stops
during operation.
The appliance works but
ground coffee does not
escape.
The set grinding level is
incorrect or difficult.
Contact local technical support if the problem is not solved or in case of other types
of faults.
Possible causes
Plug not connected.
The coffee bean container
is not inserted correctly.
The motor thermal
protection is activated
automatically after 90
seconds of continuous
operation.
The coffee beans container
is not inserted correctly.
The motor thermal
protection is activated
automatically after 90
seconds of continuous
operation.
No coffee beans in the
relative container.
Grinder blocked.
The upper part of the
grinder (9a) is missing.
Grinders worn.
Solution
Connect the plug.
Check that the coffee bean
container is correctly inserted
in the motor base.
Wait (approx. 15 minutes)
for the thermal protection to
reset.
Check
that
the
container is correctly inserted
on the motor base.
See
the
Assembly
Components paragraph to
assemble the container.
Wait (approx. 15 minutes)
for the thermal protection to
reset.
Load the coffee beans.
Remove the grinder and
check there are no objects
blocking rotation.
Insert and secure the upper
grinder (9a) in its seat.
Replace the grinders by
taking the appliance to an
authorised after-sales centre.
beans
of
EN - 9