Precautions - MOULDPRO DP 15 A 220V Notice D'utilisation Et Entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.2 - PROGRAMMING
Switch on the pump.
When switching on, the led for "OPERATE HOURS" is blinking and
is on 0 (zero). Press keys DX (right) or SX (left) to start manual
mode; the value 1 will be displayed.
For automatic programming follow the instructions below:
1. By press key + "BACKFLOW INTERV. MIN" the value 1 will be
fixed on display; this means the flow reversion will be carried out
every minute.
2. To modify the value press once the key +, the value will start
blinking; only during this stage it is possible to increase the value
(up to 9) by pressing again key +. After 3 seconds the value is
confirmed.
3. The displayed value decreases as minutes go by. To know the actual value set at the beginning,
press key + for 1 second and the actual value will start blinking.
4. To modify the value for "OPERATE HOURS" please refer to steps 2 and 3 above.
5. During automatic operation, to operate in manual mode, press twice in succession keys SX and DX.
6. Once the time set on the display "OPERATE HOURS" is finished, the pump will stop and the display
will be blinking and indicate the value 0 (zero).
7. To restart the pump press keys DX or SX; the pump will start working in manual mode and the
display "OPERATE HOURS" will show the value 1.
Scale removal can be considered complete when bubbles no longer form in the return pipe and the
solution is still acidic.
5.3 - HOW TO CLEAN THE PUMP
After descaling REMOVE THE DESCALING LIQUID FROM THE TANK and wash out the pump by
circulating clean water through it for at least 10 minutes.
Only use "MOULDPRO" chemicals in order to ensure good working and avoid damaging the
equipments.
Once the lifetime of the pump has expired, do not dispose of it with household
waste. The pump must be recycled in authorized centres and can be assimilated
to a household appliance.
During handling lift the pump and do not drag it in order to avoid damages to the tank.
Temperature of the descaling solution must never exceed 50 °C.
Flexible hoses and fittings can be damaged in time; make sure to check the seal whenever
using the pump, as indicated in the pump preparation instructions.

PRECAUTIONS

INTERVALLO INVERS.
MIN.
UMKEHRINTERVALL
MIN.
BACKFLOW INTERV.
MIN.
FUNZIONAMENTO ORE
FUNKTIONIEREN STUNDEN
OPERATE HOURS
SX
DX
MANUAL
MANUAL
BLOCK
BLOCK
7