1 1 / INSTALLING YOUR APPLIANCE
EN
• •
HOOK-UP
These hobs must be connected to the power
grid via an electrical outlet that complies with
EIC publication 60083 or an all-pole cut-off
device that complies with installation regula-
tions in effect.
When power is first supplied to your hob, or
after an extended power outage, an indicator
light will appear on the control panel. It auto-
matically disappears after approximately 30
seconds, or as soon as any touch control on
the control panel is pressed. This display is
normal and, if needed, serves as an indication
to the after-sales service staff. In all cases,
the user of the hob should disregard it.
Warning
If the power cable is damaged, it
should be replaced by the manufacturer, its
after-sales service department or by a per-
son with similar qualifications to avoid dan-
ger.
•
220-240 V monophase hook-up
Blue
Brown
N N
32A
Blue
Brown
16A
Black-grey
Green/yellow
L L
Green/yellow
N N L L
• hook-up 400V 2N
Separate the two phase wires (L1 and L2)
before hooking up.
Brown
Blue
For a 400 V 2N triphase hook-up, if your hob
malfunctions, check that the neutral conduc-
tor is properly connected.
• hook-up 2x230V 2L+2N
Separate the wires before hooking up.
-
~
Brown
Blue
• hook-up 400V 3
22
- 16A
~
Black-grey
L L 1 1 L L 2 2
N N
N N e e u u t t r r a a l l
E E a a r r t t h h
P P h h a a s s e e
~
Black-grey
N N 1 1
N N 2 2
L L 1 1 L L 2 2
N N e e u u t t r r a a l l
P P h h a a s s e e
- 16A
~
Green/yellow
- 16A
Green/yellow
E E a a r r t t h h