SPA FLOOR RETURN
This option allows you to direct part of the already filtered and heated water both via
the return nozzles and via the Spa floor drain.
The filtered water is only suctioned from the balance tank by the filter pump and is
directed toward the sand filter, the heating and the ozoniser or disinfection system,
to then be directed towards the Spa via the return nozzles and the Spa floor drain.
1
5
4
20
2
3
6
7
• SPA WITH SKIMMER
1
14
13
10
12
19
8
9
11
2
4
11
3
8
12
14
13
17
15
18
16
6
5
7
10
9
ENG
1
Overflow
2 Overflow drains
3 Balance tank
4 Filling solenoid valve
5 Level probes
6 Balance tank drain
7 Balance tank suction
8 Anti-return valve
9 By-pass valve
10 Drain
11 Spa drainpipe
12 Filter pump
13 Selector valve
14 Filter
15 Filter drainpipe
16 Electric Heating
17 Temperature probe
18 Flow detector
19 Ozonator
20 Spa return nozzles
104
1
Skimmer
2 Drain
3 Spa drainpipe
4 Filter pump
5 Selector valve
6 Filter
7 Filter drainpipe
8 Electric heating
9 Temperature probe
10 Flow detector
11 Ozonator
12 By-pass valve
13 Check valve
14 Spa return nozzles
105