ENGLISH
OPERATING MANUAL FOR
SLV 2-PHASE TRACK SYSTEM
D-TRACK
Read this short manual carefully and keep it accessible for further
reference!
SAFETY MESSAGES
Disregard of the safety messages may lead to danger of life, burning or
fire!
Installation, mounting or works on the electrical connection may only be
carried out by an approved electrician.
The product may not be modified or converted.
Do not hang or fasten anything on the product, especially no decoration.
Do not cover the product - provide free air circulation.
The rail and the individual components of the system may not be used with
components of other rail systems.
Do not direct the spots on each other.
All open rail ends must be equipped with end caps.
In case of a malfunction you may NOT touch the product or operate it
further. Disconnect the product from the power supply by an external
switch or by the fuse.
A malfunction exists when:
visible damages appear.
the product does not work properly (e.g. flickering).
smoke, steam or crackling sounds appear.
smell of burning is recognisable.
an overheating is recognisable (e.g. by discolouration of adjacent
surfaces).
Operate the product only after maintenance and examination by an
approved electrician!
This product is not intended to be used by children. Ensure that children do
not suffer any harm e.g. by burns from hot surfaces or by electrical shock.
Additional safety messages are indicated by this symbol:
USE AS DIRECTED
This product serves exclusively lighting purposes and may:
only be used with a voltage of 230V ~50/60Hz.
only be installed according to safety class I (one).
only be operated when firmly mounted on a stable, even and tilt-fixed
surface.
only be operated on normally or not flammable surfaces.
only be used in dry condition,
not in damp or dirt-endangered rooms.
not in areas of high air humidity.
not be exposed to strong mechanical loads or to strong contamination.
OPERATION
It is the responsibilty of the user to ensure the electrical and thermal
compatibility between the rail system and the luminaires connected to it.
The safety of the complete system is only assured permanentely, when all
connection between electrical components are seated tightly. Check all electrical
connections on a regular basis(every three months). Tighten these if
necessary(turn off power before!).
MAINTENANCE AND CARE
Care
Disconnect the product from the power supply and let it cool down, before
you clean the product.
Clean the product on a regular basis using a slightly moistened, soft and fluff-
free cloth. Please also note additional supplied notes on maintanance and
care.
STORAGE AND DISPOSAL
Storage
The product must be stored in a dry and clean environment. Do not strain
the product mechanically during storage.
After a damp or soiling storage the product may only be installed after
checking its condition by an approved electrician.
Disposal (European Union)
Do not dispose the product with the regular household waste! Products
marked with this sign must be disposed according to the directive (WEEE,
2012/19) on electrical and electronic devices at local collection points for such
devices!
INSTALLATION
(only by an approved electrician)
.
Switch off the mains or respectively the connection lead before doing any
works!
Use only parts, which are supplied with the product or are described as
accessories!
Inspect the product for loose parts inside the housing. When there are loose
parts inside the housing and these are not explicitly described the product may
not be installed or operated.
Use the supplied fastening material only when it is suited for the installation
background. If this is not the case use only fastening material suiting the
installation background.
Unpacking
Carefully take the product out of the packaging removing any transport
safeguards.
Before disposal of the packaging material make sure that all components of
the product are removed.
Installation place
The product is solely suited for installation on the ceiling.
Installation steps (read completely before installation)
The track may be cut using a regular metal saw. Note a straight cut!
Install the track and the components as shown in the (figure A+B).
Do not establish a closed circuit when using the T and X connector.
Use the isolating connector (art.-no. 172145) to separate the circuits (figure
C).
Electrical Connection
The product must be able to be separated by an all pole separation
from the current supply.
All stranded conductors must be equipped with end sleeves when
supposed to be connected with screw terminals.
All stranded conductors must be equipped with tin solder when
supposed to be connected with push terminals.
Connection 1 phase: The black or brown wire (live conductor) of the
connection lead are connected to clamp L1 and L2. The blue wire
(neutral conductor) of the connection lead is connected to clamp N.
The green-yellow wire (protective conductor) of the connection lead
has to be tightly connected to the earth clamp
Connection 2 phases: One of the black or brown wire (live conductor)
of the connection lead is connected to clamp L1 and the other one to
clamp L2. The blue wire (neutral conductor) of the connection lead is
connected to clamp N. The green-yellow wire (protective conductor)
of the connection lead has to be tightly connected to the earth clamp
of the product.
Close the open rail ends by applying end caps.
Attaching luminaires
Each circuit may be operated with 10A max..
Note the maximum permissible strain of the track when applying
luminaires (figure B).
See figure D1 on how to attach a luminaire.
The circuit is switched when the adapter is inserted 180° turned around
(figure D2).
Check if the product functions properly and is securely fixed!