OL Protection: 350VDC or AC RMS
Diode Test
Test Current: 1mA (approx.)
Test Voltage: 3.0VDC typical
Accuracy: ±(1.5%rdg +1dgt)
Display: Forward Junction Voltage
OL Protection: 350VDC or AC RMS
Micro Wave Diode Test
Test Current: 0.6mA (approx.)
Test Voltage: 7.0VDC typical
Accuracy: ±(3.0%rdg +1dgt)
Display: Forward Junction Voltage
OL Protection: 350VDC or AC RMS
Capacitance
Ranges: 200pF, 2, 20, 200nF, 2, 20,
200, 2000µF
Accuracy*, 200pF to 200nF: ±(1.0%
rdg +1dgt)
2µF to 200µF rgs: ±(2.0% rdg +1dgt)
2000µF range: ≤1000µF ±(3.0% rdg
+3dgt)
≥1000µF ±(5.0% rdg +5dgt)
Note: in lower ranges, substract 6 points
residual offset reading from result
Test Frequency, 200p to 2µF: 1000Hz;
20, 200µF ranges: 100Hz;
2000µF range: 10Hz
Temperature Coefficient, ≤0.5µF:
0.1%/°C; >0.5µF: 0.2%/°C
OL Protection: 0.1A/250V fast blow
fuse.
Inductance
Ranges: 2µH, 2, 20, 200mH, 2, 20,
200H
Accuracy, 200µH rg: ±(5.0%rdg
+30dgt)*
2 to 200mH: ±(3.0% +20dgt)*
2 to 200H: ±(5.0% +20dgt)*
*For values of Q ≤ 7
Test Frequency: 200µH to 2H rgs: 1000Hz;
20 and 200H ranges: 100Hz
Temperature Coefficient, ≤0.5H:
0.2%/°C; >0.5H: 0.5%/°C
OL Protection: 0.1A/250V fast blow
fuse
Transistor Test
hFE Range: 0-1000
hFE Base Current: 3µA approx.
hFE Voltage C-E: 3.0VDC approx.
I
Range, Leakage Current:
ceo
10nA to 20µA

Optional Accessories

H30Y Protective Holster
VC30 Vinyl Carrying Case
VC231 Vinyl Carrying Case (for
meter and holster)
DL243C Standard Test Lead Set
DL248C Deluxe Test Lead Set
TL245 Standard Replacement Test
Leads
TL35A Test Leads with Alligator
Clips