T H E R M O S T A T I C A D J U S T M E N T
Temperature Limitation
The temperature is limited by the safety stop to 40°C. If a
higher temperature is required, it is possible to over ride the
safety stop by depressing the safety button.
NB. It is recommended that for private domestic use the
maximum mixed water temperature be set at the following
factory set values:
Shower Mixer 43°C
Bath ⁄Shower 43°C
Temperatures can be set by following the procedures on
page 63. This ensures that after correct installation the
outlet temperature of the water can never exceed 43°C.
To guarantee a smooth running of the thermostatic element,
it is necessary from time to time to turn the thermostat from
total hot to total cold. The thermostatic mixer valve should
be checked annually by a qualified person to ensure
correct operation.
The mixer is fitted with check valves (page 69 - 72 pos.
94074000 / 92594000) and filters (page 69 - 72 pos A).
If the water flow drops the filters need to be cleaned. For
that purpose please follow the steps 1 - 13 on page 66.
Calibrating Thermostat
If the temperature reading is different to the showering
temperature, follow the steps 1 - 3 on page 63.