Special provisions for mobile homes:
Exhaust vent must be securely fastened to a noncombustible
portion of mobile home and must not terminate beneath the
mobile home. Terminate exhaust vent outside.
Mobile home exhaust installation
Determine vent path:
Select route that will provide straightest and most direct
path outdoors.
Plan installation to use fewest number of elbows and turns.
When using elbows or making turns, allow as much room
as possible.
Bend vent gradually to avoid kinking.
Use as few 90° turns as possible.
Determine vent length and elbows needed for best drying
performance:
Use following Vent System Chart to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specifi ed
in Vent System Chart. Exhaust systems longer than those
specifi ed will:
Shorten life of dryer.
Reduce performance, resulting in longer drying times
and increased energy usage.
Vent System Chart
Number of
Type
90° turns
of vent
or elbows
0
Rigid metal
1
Rigid metal
2
Rigid metal
3
Rigid metal
4
Rigid metal
Box/louvered
Angled
hoods
hoods
64 ft. (20 m)
58 ft. (17.7 m)
54 ft. (16.5 m)
48 ft. (14.6 m)
44 ft. (13.4 m)
38 ft. (11.6 m)
35 ft. (10.7 m)
29 ft. (8.8 m)
27 ft. (8.2 m)
21 ft. (6.4 m)
Vent System Chart
(29" Wide Long Vent 65212610
and 75212610 Models Only)
Number of
Type
90° turns
of vent
or elbows
0
Rigid metal
1
Rigid metal
2
Rigid metal
3
Rigid metal
4
Rigid metal
5
Rigid metal

INSTALL VENT SYSTEM

1.
Install exhaust hood
Install exhaust hood and use caulking compound to seal
exterior wall opening around exhaust hood.
2.
Connect vent to exhaust hood
Vent must fi t over the exhaust hood. Secure vent to exhaust
hood with 4" (102 mm) clamp. Run vent to dryer location using
straightest path possible. Avoid 90° turns. Use clamps to seal
all joints. Do not use duct tape, screws, or other fastening
devices that extend into interior of vent to secure vent,
because they can catch lint.
Box/louvered
or angled hoods
160 ft. (48.8 m)
150 ft. (45.7 m)
140 ft. (42.7 m)
130 ft. (39.6 m)
120 ft. (36.6 m)
110 ft. (33.5 m)
12" min.
(305 mm)
12" min.
(305 mm)