Installation Clearances; Dryer Dimensions - Kenmore W10850308A Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION CLEARANCES

For each arrangement, consider allowing more space for ease of
installation and servicing; spacing for companion appliances and
clearances for walls, doors, and floor moldings. Space must be
large enough to allow door to fully open. Add spacing on all sides
of dryer to reduce noise transfer. If a closet door or louvered door
is installed, top and bottom air openings in door are required.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.

DRYER DIMENSIONS

22
/
"
3
4
(578 mm)
(660 mm)
13
/
"
3
4
(349 mm)
26"
(660 mm)
A. Wide opening side-swing door
B. Wide opening hamper door
NOTE: Minimum height of leveling legs should be 1/2" (13 mm),
4"
or to match the height of the accompanying washer.
(101 mm)
Back View
30
"
/
1
4
(768 mm)
1
/
"
1
4
(32 mm)
/
"
4
/
"
1
3
2
4
9
/
"
1
(121 mm)
4
(235 mm)
NOTE: Most installations require a minimum 5
clearance behind the dryer for the exhaust vent with elbow.
See "Venting Requirements".
6
26"
42
/
"
1
2
(1080 mm)
/
"
1
2
(13 mm)
A
(737 mm)
42
/
"
1
2
(1080 mm)
/
"
1
2
(13 mm)
B
1
/
"
1
4
(32 mm)
14
/
"
1
2
9
/
"
(368 mm)
1
4
(235 mm)
/
" (140 mm)
1
2
Spacing for recessed area or closet installation
The dimensions shown are for the minimum spacing allowed.
Additional spacing should be considered for ease of installation
and servicing.
Additional clearances might be required for wall, door, and
floor moldings.
Additional spacing of 1" (25 mm) on all sides of the dryer
is recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilitation openings are
acceptable.
29"
Companion appliance spacing should also be considered.
(737 mm)
Installation Spacing
(356 mm)
29"
5
/
"/0"
1
2
(140 mm/0 mm)
Recommended/Minimum spacing
Mobile home - Additional installation requirements:
This dryer is suitable for mobile home installations. The installation
must conform to the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard
for Mobile home construction and Safety, Title 24, HUD Part 280)
or Standard CAN/CSA-Z240 MH.
Mobile home installations require:
All dryers:
Metal exhaust system hardware, available for purchase
from your dealer. For further information, call 1-844-553-6667
(U.S.) or 1-800-469-4663 (Canada).
Special provisions must be made in mobile homes to
introduce outside air into dryer. Openings (such as a
nearby window) should be at least twice as large as
dryer exhaust opening.
For gas dryers mobile home installations:
Mobile Home Installation Hold-down Kit Part Number
W10432680 is available to order. For further information,
call 1-844-553-6667 (U.S.) or 1-800-469-4663 (Canada).
14" max.
1"/0"
(25 mm/0 mm)
3"/3"
(76 mm/76 mm)
48 in.
2
/48 in.
(310 cm
2
/
310 cm
2
)
18"/18"
(457 mm/
457 mm)
2
24 in.
/24 in.
(155 cm
2
/
155 cm
2
)
1"/1"
(25 mm/
25 mm)
3"/3"
(76 mm/76 mm)
2
2

Publicité

Table des Matières