5.
Connect remaining wires
Place hooked ends of remaining direct wire cable wires
under outer terminal block screws (hooks facing right).
Squeeze hooked ends together and tighten screws. Finally,
reinstall terminal block cover. Secure cover with hold-down
screw. Now, go to "Venting Requirements."
3-wire Direct Wire Connection
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
1.
Prepare your 3-wire cable
for direct connection
Direct wire cable must have 5 ft. (1.52 m) of extra length so
dryer may be moved if needed.
Strip 3
/
" (89 mm) of outer covering from end of cable. Strip
1
2
insulation back 1" (25 mm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape wire ends
into hooks.
2.
Remove center screw
Remove center terminal block screw (B).
3.
Connect neutral wire
Place hooked end of neutral wire (white
or center) (C) of direct wire cable under
center terminal block screw (B). Squeeze
hooked end together. Tighten screw.
4.
Connect remaining wires
Place hooked ends of remaining direct wire cable wires under
outer terminal block screws (hooks facing right). Squeeze
hooked ends together and tighten screws. Finally, reinstall
terminal block cover. Secure cover with hold-down screw.
Now, go to "Venting Requirements."
Optional 3-wire Connection
with External Grounding
You must verify with a qualified electrician that this
grounding method is acceptable before connecting.
1.
Prepare to connect neutral
ground wire and neutral wire
E
B
Remove center terminal block screw (B). Remove neutral ground
wire (E) from external ground conductor screw (A).
C
B
A
B
15