Alarm Signals

Mess
"EE"
Data or memory failure
"rPF"
Thermostat Probe failure
"EPF"
Evaporator Probe failure
"i1P"
"i2P"
Insert probe 1, 2, 3, failure
"i3P"
"rtC"
Real Time Clock data lost
"rtF"
Real Time Clock failure
"HA"
Maximum temperature alarm
"LA"
Minimum temperature alarm
Fast freezing interrupted by
"FF"
shortpower failure
Fast freezing interrupted by long
"PFA"
power failure
Max duration of the cycle is
"OCF"
expired
"EA"
External alarm
"CA"
Serious external alarm
"dA"
Door open alarm
Cause
Alarm output ON; Other outputs unchanged
Alarm output ON; Compressor output according to parameters
"COn" and "COF"
Alarm output ON; Defrost termination is timed; No temperature
control on fans.
Alarm output ON; Other outputs unchanged; The cycle is made by
time
Alarm output ON; Other outputs unchanged;
Alarm output ON; Other outputs unchanged; The date and the
duration of the cycle are not available.
Alarm output ON; Other outputs unchanged
Alarm output ON; Other outputs unchanged.
Alarm output ON; The freezing cycle restart from the same point at
which was interrupted.
Alarm output ON; The freezing cycle restart from the current phase.
Alarm output ON; Other outputs unchanged. In any case the cycle
ends when the final temperature is reached
Alarm output ON; Other outputs unchanged.
Alarm output ON; Other outputs OFF.
Alarm output ON; Other outputs unchanged.