Plug Configurations

Units are supplied from the factory with an electrical cord and
plug. Plugs are supplied according to the application.
WARNING
ELECTRIC SHOCK HAZARD: Plug unit into a properly
grounded electrical receptacle of the correct voltage,
size, and plug configuration. If plug and receptacle do not
match, contact a qualified electrician to determine and
install proper voltage and size electrical receptacle.
NOTE: Receptacle not supplied by Hatco.

Electrical Rating Chart

Model
Voltage
FWM-1B,
120 V
FWM-1MB

Dimensions

Width
Model
(A)
FWM-1B,
9-5/8"
FWM-1MB
(244 mm)
A
C
D
Front View
Form No. FWMM-0121
Watts
Amps
1350 W
11.3 A
Depth
Height
(B)
(C)
22-13/16"
11-5/8"
(579 mm)
(295 mm)
Plug Configurations
Plug Configuration
NEMA 5-15P
Footprint
Footprint
Width (D)
Depth (E)
7-7/8"
13-1/2"
(200 mm)
(343 mm)
B
F
E
Side View
5

SPECIFICATIONS

Unit Weight
22 lbs. (10 kg)
Base
Depth (F)
14-1/4"
(362 mm)