Asco JOUCOMATIC SENTRONIC 601 Série Manuel D'installation page 13

Masquer les pouces Voir aussi pour JOUCOMATIC SENTRONIC 601 Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

G 1/8 (Ø 3 mm) G 1/4 (Ø 6 mm) - G 1/2 (Ø 12 mm) - G1 (Ø 20 mm)
View on the soldered wires
side of female connector
SETTING
0 - 10V
ADJUSTABLE
Output
or
BY POTENTIOMETER
Input
PRESSURE SWITCH OUTPUT
OR
OR
OR
*
External feedback value input if the valve is configurated for external sensor
WARNING :
1) It is necessary to use a power supply with 24V direct current, ± 10% tolerance with a
max. 10% ripple (no supply per diode bridge). Over voltage or a ripple rate of over 10%
can damage the electronic.
2) Max current of pin 7 is 500 mA (output NPN/PNP). Pin 7 has a short circuit and a
overload protection.
3) If you connect a relay (inductive load) to pressure switch output, you must use a
freewheel diode or a varistor.
4) Don't solder to unused pins on the female connector.
5) In case of an interruption in the pressure supply, shut off the power supply (+24V) or
switch the set point to zero to avoid excessive heating of the coil.
6) Grounding for personal protection must be done at the PE-thread (ØM4) on the body.
7) Use a shielded cable for EMC-protection.
Connect the shield to ground and to the connector body.
WIRING CONNECTOR
ON SENTRONIC WITH ANALOGIC CONTROL
PRESSURE FEEDBACK
0 - 10 V (option 0 - 20mA ou 4 - 20mA)
*
500
500
500
500
GB
PE
ØM4
2
13

Publicité

Chapitres

Table des Matières
loading

Table des Matières