99 = 9.9 seconds
• The buzzer beeps and the yellow FBK led turns on: The
reader Is awaiting other programming commands.
The reader returns to normal operations turning on the
RDY led and turning off the FBk led if no operations are
performed within 30 seconds or the E key is pressed.
ROOM LIGHT SENSOR PROGRAMMING FIG.I
After entering the Master code/reading the Master badge or
within 30 seconds of the previous programming:
• Hold down the "3" key until a second beep sounds and the
yellow led blinks (2 seconds)
• Enter the value of the room light sensor threshold (from 0
to 9) and press OK:
0= Sensor and OUT2 output disabled
1..9 = sensor on (default 5)
With value = 1, the OUT 2 relay output (stairwell lights on)
will be activated in poor/lacking light conditions (semi-
darkness), with value = 9, the OUT 2 relay output (stairwell
lights on) will only be activated in moderate lighting
conditions (dusk);
• The buzzer beeps and the yellow FBK led turns on: The
reader Is awaiting other programming commands.
The reader returns to normal operations turning on the
RDY led and turning off the FBk led if no operations are
performed within 30 seconds or the E key is pressed.
ROOM LIGHT SENSOR OPERATING TEST FIG.J
After entering the Master code/reading the Master badge or
within 30 seconds of the previous programming:
• Hold down the "3" key until a second beep sounds and the
yellow led blinks (2 seconds)
• Enter the value of the room light sensor threshold (from 0
to 9) followed by 0:
The AXXEDO Q.BO SA reader tests room lighting:
if room lighting Is under the set threshold, OUT 2 relay
output - stairwell lights on - will be activated.
if room lighting is over the set threshold, OUT 2 relay output
will not be activated; to check the room lighting level enter,
without exiting programming, a new value followed by 0
to check whether the OUT 2 relay output – stairwell light
on – activates.
For example: entering
Master + holding down key 3 + 6 + 0
the reader checks whether room lighting is under or over
threshold 6.
Without exiting programming, enter
4 + 0
the reader checks whether room lighting is under or over
threshold 4 and so on.
• To confirm the level, enter the value of the room light sensor
threshold again (from 0 to 9) and press OK:
• The buzzer beeps and the yellow FBK led turns on: The
reader Is awaiting other programming commands.
The reader returns to normal operations turning on the
RDY led and turning off the FBk led if no operations are
performed within 30 seconds or the E key is pressed.
BUZZER ON/OFF FIG.K
After entering the Master code/reading the Master badge or
within 30 seconds of the previous programming:
• Hold down the "4" key until a second beep sounds and the
yellow led blinks (2 seconds)
• Enter:
14 -
AXXEDO Q.BO SA
INSTALLATION MANUAL
0+ OK to turn off the buzzer
1+ OK to turn on the buzzer (default)
• The buzzer beeps and the yellow FBK led turns on: The
reader Is awaiting other programming commands.
The reader returns to normal operations turning on the
RDY led and turning off the FBk led if no operations are
performed within 30 seconds or the E key is pressed.
BADGE CODE RECOGNITION FIG.L
After entering the Master code/reading the Master badge or
within 30 seconds of the previous programming:
Hold down the "5" key until a second beep sounds and the
yellow led blinks (2 seconds)
Enter:
0 + OK - If the codes printed on the badge are entered on
the keyboard, they are not recognised (default).
NOTE: if badge codes are saved using the keyboard, they
are still recognised.
1 + OK - If the codes printed on the badge are entered on
the keyboard, they are recognised.
• The buzzer beeps and the yellow FBK led turns on:
The reader Is awaiting other programming commands. The
reader returns to normal operations turning on the RDY led
and turning off the FBk led if no operations are performed
within 30 seconds or the E key is pressed.
MEMORY RESET (ONLY USER CODES) FIG.M
After entering the Master code/reading the Master badge or
within 30 seconds of the previous programming:
• Hold down the "8" key until a second beep sounds and the
yellow led blinks (2 seconds)
• Enter 00 followed by OK
• The buzzer beeps and the yellow FBK led turns on: The
reader Is awaiting other programming commands.
The reader returns to normal operations turning on the
RDY led and turning off the FBk led if no operations are
performed within 30 seconds or the E key is pressed.
PARAMETER RESET FIG.N
With this operation, OUT 1 Timer, OUT 2 Timer, room light sensor
trip threshold and buzzer functions are reset to default values
(relay output timer = 1 second, Room light sensor threshold =
5, Buzzer = on, badge code recognition = off ).
After entering the Master code/reading the Master badge or
within 30 seconds of the previous programming:
• Hold down the "9" key until a second beep sounds and the
yellow led blinks (2 seconds)
• Enter 00 followed by OK
• The buzzer beeps and the yellow FBK led turns on: The
reader Is awaiting other programming commands.
The reader returns to normal operations turning on the
RDY led and turning off the FBk led if no operations are
performed within 30 seconds or the E key is pressed.
9) USE FIG.1
Place the saved card/transponder at least 5 cm from the reader
or enter the saved user code and press Ok.
If the badge/transponder or user code is recognised, the reader
will activate OUT1 or, if programmed, OUT2.
With DIP SWITCH 2 ON, hold down key E for 2 seconds to
only activate the OUT2 output.