BFT Stand Alone AXXEDO Q.BO SA Instructions D'installation page 13

Kit de contrôle des accès résidentiels
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
LED
COLOUR
It briefly blinks each time a key is
FBK
Yellow
pressed. It is used with different
signals during reader programming.
It turns on to signal a code/badge
OK
green
was recognised and to signal relay
output activation.
FUNCTION
BUZZER
1 beep
followed by a
Read or
high tone
enter a
1 beep
User code
followed by a
low tone
Keyboard
1 tone (tick)
use
Program-
1 beep
ming
Program-
1 beep
ming
7) ROOM LIGHT SENSOR
The reader has a room light sensor (on the front of the reader).
The room light sensor automatically activates relay output
OUT 2 to turn on lights when reading/entering a valid user
code (with consequent OUT 1 door opening control) if the
room lighting is under the set threshold.
The room light sensor can be turned on/off and adjusted using
the reader programming procedure.
Furthermore, the backlit keyboard leds turn on following the
light sensor; if the sensor indicates sufficient light, they still turn
on for 30 seconds when pressed; if the sensor is turned off, they
turn on following the sensor set on the intermediate threshold.
8) PROGRAMMING
Always press OK after entering the Master code.
During this programming phase (Master code programming,
adding or deleting a transponder/User code, relay output
timers, etc.), if the procedure is interrupted for 30 seconds
or the E or invalid key is pressed or invalid value entered, the
reader will signal an error (1 buzzer beep) and automatically
exit the programming procedure.
The reader is supplied fully deprogrammed.
The various available programs are described below:
MASTER CODE PROGRAMMING/EDITING FIG.D
The Master code, if entered from the keyboard, must be at
least 4 digits long.
After entering the master code/reading the Master badge or
within 30 seconds of previous programming or after during
DIP SWITCH 1 ON:
• Hold down the "0" key until a second beep sounds and the
FBK led blinks (2 seconds)
• Read a new Master badge or enter a new Master Code on
INSTALLATION MANUAL
MEANING
MEANING
Correct user code (valid)
read or entered
Incorrect user code (inva-
lid) read or entered
Each time a key is pressed
and when a key is held
down for 3 seconds in
programming mode.
Programming procedure
exited due to procedure
interruption (30-second
timeout or E key pressed)
Programming procedure
exited due to invalid key
pressed or value entered.
the keyboard and press OK.
• The buzzer beeps followed by a high tone, the yellow FBK
led turns on: The reader Is awaiting other programming
commands.
The reader returns to normal operations turning on the
RDY led and turning off the FBk led if no operations are
performed within 30 seconds or the E key is pressed.
ENTERING USER CODES FIG.E
• Read the Master badge or enter the Master code on the
keyboard.
Make sure the blue RDY led turns off and the yellow FBK
led turns on.
• Read the badge/transponder or enter the User code
(login) and press OK.
The yellow FBK led blinks once if the code is correctly saved.
The red ERR led will blink 4 times if the read/entered User
code is already saved.
• Several User codes can now be entered repeating the
procedure described in point 2.
• End the procedure by pressing E on the reader keyboard
or by reading the Master badge.
Make sure the blue RDY led turns back on.
DELETING USER CODES FIG.F
• Read the Master badge twice or enter the Master code
twice on the keyboard.
Make sure the blue RDY led turns off and the yellow FBK
led and red ERR led turn on.
• Read the badge/transponder or enter the User code to
be deleted and press OK.
The yellow FBK led blinks once if the code is correctly
deleted.
The red ERR led will blink 4 times if the read/entered User
code is inexistent.
• End the procedure by pressing E on the reader keyboard
or by reading the Master badge.
Make sure the blue RDY led turns back on.
OUT 1 TIMER FIG.G
After entering the Master code/reading the Master badge or
within 30 seconds of the previous programming:
• Hold down the "1" key until a second beep sounds and the
yellow led blinks (2 seconds)
• Enter the timer value to be assigned to the relay output
(from 00 to 99) and press OK:
00 = latching mode
05 = 0.5 seconds
10 = 1 second (default)
...
99 = 9.9 seconds
• The buzzer beeps and the yellow FBK led turns on: The
reader Is awaiting other programming commands.
The reader returns to normal operations turning on the
RDY led and turning off the FBk led if no operations are
performed within 30 seconds or the E key is pressed.
OUT 2 TIMER FIG.H
After entering the Master code/reading the Master badge or
within 30 seconds of the previous programming:
• Hold down the "2" key until a second beep sounds and the
yellow led blinks (2 seconds)
• Enter the timer value to be assigned to the relay output
(from 00 to 99) and press OK:
00 = latching mode
05 = 0.5 seconds
10 = 1 second (default)
...
13
AXXEDO Q.BO SA -

Publicité

Table des Matières
loading

Table des Matières