CHANNEL 2
TECHNICAL SPECIFICATIONS
Power
230V AC +/- 10% OR 12/24V AC DC
Max. Power consumption
0.5A
Outputs
Fixed outputs
1 Relay 1A/30V
Optional outputs (cards)
3 Relays 1A/30V
Available codes
2.097.152.281 Millions
Encryption technology
Hopping code
Key Encryption
64 bits
Detection of errors during transmission
2 CRC bits
Number of codes
255 different codes
Fuction selection:
1 relay
Memorizes in function of the code
2 relays or more
Predeterminated function or program
Latch relays
Position 1 programable
Frecuency
433.92MHz OR 868,35MHz
Certificates
ETS300-220/ETS300-683
Spurious emissions
< -57dBm
Sensitivity
< -104dBm
Range
60m
Access control
YES
Temperature
0 to 70º
Antenna
17cm / 8,5cm
WARNING!!
Instruction Manual
- Smart control product range, intelligent code, safe, reliable and cannot be copied.
- 220V a.c. receiver for any automatic system
- Multy function selection.
- Channel outputs can be amplified using additional card inputs
- Option to use Smart transmitters with Hopping Code or fixed code.
OPTIONS SELECTOR
OPTION 1 - Option function relays / Predetermined functions
ON
CHANNEL 3
OFF
OPTION 2 - Hopping Code / fixed code
CHANNEL 3
ON
OFF
OPTION 3 - Multi- Memorization / manual memorization
ON
OFF
OPTION 4 - Multi- Relay 1 Latch/ Relay 1 Pulse
ON
OFF
Note 1:
If transmitters Smart with Hopping Code are used (Dip 2 in ON position), all the transmitters will have a different code.
If transmitters Smart with fixed code are used (Dip 2 in OFF position), you can use the same code for different transmitters. E.G You can assign a
code for a parking having 255 different parking lots, or the same code for all the parking using unlimited transmitters which are the same in each
installation.
TERMINAL CONNECTIONS
POWER SUPPLY
220V
AN ACCESSIBLE SWITCH, TO TURN OFF THE EQUIPMENT,MUST BE INSTALLED FOR SYSTEMS THAT ARE ALWAYS CONNECTED.
BEFORE INSTALLING MAKE SURE THE SUPPLY VOLTAGE IS SWITCHED OFF
(SMR 220V C4)
This assigns the function (Button) to activate the relays according to the order of memorization of the first three codes. (only valid for maximum
3 relays)
The function (button) of the 1st memorized code is assigned to the 1st relay.
The function (button) of the 2nd memorized code is assigned to the 2nd relay.
The function (button) of the 3rd memorized code is assigned to the 3rd relay.
Default relays
Function (button) 1, first relay.
Function (button) 2, second relay.
Function (button) 3, third relay.
Function (button) 4 (proximity channel), fourth relay
For Smart transmitters with Hopping Code
For Smart transmitters with fixed code
Memorization systems available, a), b) y c) (see below)
Allows for manual memorization system a), and special functions system c) (see below)
Relay 1 Latch mode.
Activated – Deactivated – Activated ..., according to signal
Relay 1 Pulse mode.
Relay maintains activated during signal reception (Deadman)
RELAY OUTPUT
C
Common relay 1
NC Normally closed contact
NO Normally open contact
RELAY
+ Access control power suply. Positive
- A
s
-
+
S
SPROX
.
SPROX INPUT
ccess control power suply. Negative
access control. Signal