1. Before start-up, note the following!
The pump can be connected to any shock-proof plug
which has been installed according to regulations.
The plug must have a supply voltage of 230 V ~ 50
Hz. Fuse min. 6 Amp.
Caution!
When the pump is to be used near swimming pools
or garden ponds and in their area of protection, it
must be equipped with a ground-fault circuit
interruptor with a nominal trip current of max. 30 mA
(according to VDE 0100, part 702 and 738).
The pump musat not be operated while people are in
the swimming pool or in the garden pond!
Please contact your electrician!
Attention!
(Important for your own security)
Before starting to run your new submersible pump,
please have the following items checked by an expert:
Ground connection
Zero conductor
Fault current breaker switch must correspond the
the safety regulations of the power plants and
they must work faultessly.
The electrical connections must be protected from
moisture.
If there is danger of looding, the electrical connections
must be taken to higher ground.
Circulation of aggressiv fluids, as well as the
circulation of abrasive materials must be avoided at
all costs.
The submersible motor-driven pump must be
protected from frost.
The pump must be protected from running dry.
Access on the part of children should also be
prevented with appropriate measures.
2. Layout (Fig. 1)
1 Carry handle with cable rewind
2 Hose connection
3 Fastening nut
4 Pump housing
5 Intake cage
6 Mains cable
3. Fitting the carry handle (Fig. 2/3)
Connect carry handle (1) to pump (Fig. 2).
Secure carry handle (1) with fastening nut (3)
(Fig. 3).
12:42 Uhr
Seite 7
4. Intended use
The submersible pump you have purchased is
designed to pump water with a maximum
temperature of 35 °C.
This pump must never be used to pump other liquids,
especially engine fuels, cleaning agents and other
chemically-based products!
5. Installation
The submersible pump can be installed either:
Stationary with fixed tubing
or
Stationary with flexible hose line
Note!
When installing, never mount the pump by simply
hanging it on the pressure line or the power cable.
The submersible pump must be hung up with the
provided carry handle or it must rest on the bottom of
the shaft. To ensure that the pump works properly,
the bottom of the shaft always must be free of sludge
and other contaminants. If the water level is too low,
the sludge in the shaft can quickly dry out and hinder
start-up of the pump. This is why it is necessary to
regularly check the submersible pump (carry out trial
start-ups).
Note!
The pump shaft should measure at least 40 x 40 x
50 cm.
6. Mains supply
Your new submersible pump is equipped with a
shock-proof plug according to regulations. The pump
is designed to be connect-ed to a 220/230 V ~ 50 Hz
safety socket.
Make sure that the socket is sufficiently secured
(min. 6 Amp.) and is in excellent condition. Introduce
the plug into the socket and the pump is ready to go.
Important Note!
If the mains cable or plug suffers any damage from
external action, repairs to the cable are prohibited.
Important!
This work may only be performed by a qualified