Alarm
Threshold indicator
High or low
i)
Measurement stop
Depending on the configuration, the SPY RF can stop recording or not. The different options are:
Rolling memory: once the memory is full, the new values replace the old ones.
Full memory: the recorder stops when its memory is full.
With the software: you can put the SPY RF in standby mode with Sirius when you do not use your
recorder.
With the pushbutton: this option is valid only if the SPY RF is configured in transport mode with a start by
pushbutton.
j)
Auto control or top zone
The type of action depends on the SPY RF configuration.
TOP ZONE = Transport mode
This function enables you to customise an action of measurement check-up. You just have to press shortly on
the pushbutton.
The action is recorded and will appear on the curve when you process the data with your software Sirius.
+
Value measured
Flashes every 15"
and
AUTO CONTROL = Storage mode
+
+
Alarm LED (red):
Flashes every 15''.
To stop your SPY RF, press between 5
and 10" on the button:
The 2 LEDs are on and then flash
-
alternatively.
The screen goes off, Halt goes on.
-
T° OK: green LED is
on during 10".
Alarm LED (red) is on
during 10".
16