Wedi Sanoasa Libertà 07-66-70/000 Manuel De L'utilisateur page 30

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Maximum running time before descaling
As the following table shows, the requirement for manual descal-
ing depends on the water quality and running time:
Softened
0.01 – 01° dH
Soft
1.00 – 03° dH
Average
3.00 – 10° dH
Hard
from 10° dH
Sulphamic acid descaling agent: 50 ml
Solvent descaling agent: 1 pack (80 g)
Generator output: VB 6.6 KW
Steam generator control unit
The steam generator is equipped with a control unit. This control
unit is operated via a console. By pressing the individual controls
on the operating console, different states can be brought about
in the Sanoasa Wellness Multicentre cabin. The individual func-
tions are described below. More detailed or supplementary de-
scriptions can be found in the technical manual supplied.
Control unit with the following console functions:
1
LIGHT for switching the lights on/off (non-functional)
2
ON/ OFF for switching the steam generator on/off
3
TEMP for setting the temperature
4
TIME for setting the time
5
DOWN for reducing the temperature / time
6
UP for increasing the temperature / time
7
Display
30
Code lock for preventing unwanted adjustment of the
temperature
How to activate and reactivate the code lock:
First set the desired temperature.
Then wait for at least 20 seconds. Keep the DOWN button (5)
1100 hours
pressed and press TEMP (3) at the same time.
The code lock, which prevents changes to the temperature set-
300 hours
ting, is now activated. The lock can be released again by pressing
the DOWN (5) button and OFF (2) at the same time.
150 hours
Rocker switch in the equipment room for switching the LED
50 hours
lamps in the cabin roof on and off:
How to use the rocker switch
(functional sequence for different settings):
1 x brief press of button to switch on/off (last colour combina-
tion is retained)
2 x brief press of button to set all 3 colours to 100% intensity
1 x extended press of button to set the colour selection with the
effect that the colour remains as it has been set
Press button for 20 seconds to set an automatic colour se-
quence (colours change constantly)
Toggle switch in the equipment room for switching the
fibre-optic light guides and halogen spotlights in the cabin
roof on and off
How to use the rocker switch (functional sequence for different
settings):
The fibre-optic lamps are switched on and off by the built-in tog-
gle switch in the equipment room. The colour sequence changes
independently.
The halogen spotlights are switched on and off by the built-in tog-
gle switch in the equipment room. There is no colour sequence.

Publicité