If, in on-state or off-state, the permissible temperature of the MOSFET
is reached, this is indicated by a slow flashing red LED (approximately
1 x per second). Vaporing is not possible then. The device needs to
cool down until the flashing stops, before it is ready for use again!

While pressing the button (vaporing)

Okay:
• The green LED should light up only when the device is ready and you
press the button! From 3.0V, the red LED will pulse additionally to the
green LED (the lower the voltage, the faster the pulses). At 2.6V the
green LED goes out and the red LED stays on for about 10 seconds
more, then the device shuts down completely! You need to insert a
new battery.
Error:
• The device does not start to vapor and the green LED will not light
up! The key lock is activated or the Vireo has been completely shut
down before due to low battery voltage or an error.
• The red LED lights up for about 10 seconds and then the device
shuts down completely! The minimum permissible battery voltage of
2.6 V was reached.
• Fast flashing red LED for about 10 seconds, then normally complete
shutdown! The overload protection has triggered, probably due to a
short circuit in the evaporator or moisture.

Without pressing the button (sleep)

Okay:
• No display, neither red nor green.
Error:
• Suddenly, the red LED lights up for about 10 seconds and then the
device shuts down completely!
The minimum permissible battery voltage of 2.6 V was reached.
• Fast flashing red LED for about 10 seconds, until the removal of
© 2015 SmokerStore GmbH