Optical Signals; Self-Test After Inserting The Battery; Permanent Over-Temperature Protection - TAIFUN Vireo Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Taifun Vireo
Operation manual
device against accidental activation! The key-lock is not suitab-
le to leave the device UNATTENDED (drawer, purse, table, glove
compartment, etc.). Each electronic CAN react uncontrollably by
liquid entry or technical failures and MIGHT turn on the device
and / or cause a fire!
We can not guarantee a 100% secure device, despite our security fea-
tures! ANY electronic device ALWAYS has an element of risk, as long as
it is connected to a power supply!
Consider the possible consequences (A standby device may just turn on,
but an e-cigarette may start to vapor with uncontrolled high currents).
It may take several hours until an ingress of liquid causes mal-
function. The only SAFE PROTECTION is the removal of the battery!

OPTICAL SIGNALS

Self-test after inserting the battery

Okay:
• The red LED lights up for about 1 second and then goes out (<Red>
... <Off>)
Error:
• The red LED lights up and stays lit up permanently (<Red> ...)!
The photocell of the magneto-optical switch is not working properly.
This happens, for example, if you insert the battery while pressing the
button. Moisture in the device may cause this malfunction as well.
• The red LED lights up, goes out shortly, lights up again and stays lit
up permanently (<Red> ... <Off> ... <Red> ...)! There is an over-
load or short circuit in the evaporator. Liquid entry may be the cause,
too. In both cases, only a power off resets the device (remove the
battery cover and tighten again).

Permanent over-temperature protection

Once the battery is installed and the device has not been switched off,
the temperature of the MESFET is permanently monitored!