3 Putting into operation
3.2 Mounting the wire guide
3.2.1 Liner
3.2.2 PA liner
3.3 Connecting the cable assembly
EN - 6
To be used for steel wires.
1 Lay down the cable assembly straight and unscrew gas nozzle and contact
tip from the torch neck.
2 Unscrew nut from the central connector and slide liner through the wire
conduit up to the retaining nipple.
3 Screw down nut again by hand and cut off excess length of the liner flush
with the torch neck or tip adaptor.
4 Unscrew nut and pull out liner.
5 Sharpen the liner beginning to an angle of approx. 40° and debur the
edge.
6 Slide sharpened liner through the wire conduit up to the retaining nipple
and screw down nut and tighten it using a multiple wrench.
7 Screw in contact tip and attach gas nozzle.
To be used for aluminium, copper, nickel and stainless steels.
1 Sharpen beginning of PA liner using the ABICOR BINZELsharpener at an
angle of about 40° and slide PA liner through the wire conduit until a
noticeable resistance is felt in the contact tip.
2 Slide clamp nipple, O-ring and nut onto PA liner and tighten the nut under
tension.
3 Mark overlength of the PA liner in front of the wire feed rolls and cut it off at
the mark using the ABICOR BINZEL cutter.
4 Sharpen the cutting point.
NOTE
• For PA liners of outer diameter 4.00 mm, the capillary tube in the
intermediate joining section must be replaced with a guide tube.
1 Join central connector and central socket at the wire feed unit and secure
them with the connection nut.
2 Properly mount the connections for water supply/return, shielding gas and
control lead plug.
®
ABIMIG
GRIP W