6.5 C
ALIBRATION
- Exhaustion of the electrolyte contained in the refill see Par 4 – Refill Replace
- Pollution of the tip (eg. If you performed a test on a piece of dirt) see Par 5 – Tip Replace
It is recommended to perform the calibration test after a prolonged storage period.
6.6 F
T
REE
EST
stainless steel between a maximum value (
FREE TEST
Press
to return to the
6.7 Q
C
UALITY
ONTROL
be left blank, press
); after testing, the instrument will return to this window, giving the possibility to enter the next serial
number. To change the value, press
SERIAL N
Insert the
° and press
After pressing
the test will start and a graphic bar will show the progression of the test (duration: 15 seconds).
After testing, the display shows the numeric value of the quality of the passive layer of stainless steel between a maximum
GOOD
value (
) and totally not passive (
Press
to return to the insertion of the serial number -thus maintaining the current session and the Project N°- or press the
MENU
button to end the session and return to the main menu.
NOTE: The tester has 50 memory blocks; once used all the available cells, to perform new QC tests it will be necessary to clear
the memory using the provided software function (see. section 8.3.2 – Deleting Tests – User ID).
PASSI TEST PLUS
To access the calibration control function, from the main menu, select
; scroll with the arrows to the
calibration plate supplied, then press
OK
there will be an
message confirming proper calibration.
In the eventuality that the calibration cannot be completed, a message to verify the
CHECK TIP / REFILL
cartridge and/or tip;
The loss of the calibration can be in fact caused by two factors:
The Free Test function allows to make a passivation test without saving the data in
memory. To access this feature, from the main menu, select
FREE TEST
then
(press
).
Position the probe on the test piece and press
After pressing
the test will start and a graphic bar will show the progression of the
test (duration: 15 seconds).
After testing, the display shows the numeric value of the quality of the passive layer of
GOOD
) and totally not passive (
MENU
section or press
to return to main menu.
From the main menu, select
(press
)
To access the quality control function, you must login using their username / password,
Settings
previously recorded in the
Once logged in, you are requested for
tests of the current session. Enter the project No and press
blank, pressing the
key)
SERIAL N°
Than it is required the
and enter the data using the keyboard.
, than position the probe on the test piece and press
BAD
).
16
CALIBRATION
selection and place the probe on the
. A 5 seconds calibration test will start, after which
will be displayed.
to begin the test.
BAD
).
NEW TEST
(press
) and subsequently
section. (see par. 6.4 User ID / Password setting)
PROJECT N°
., which will remain stored during all the
. This data will be stored for the current test (the field can
to begin the test.
SETTINGS
and press
NEW TEST
(press
) and
QUALITY CONTROL
(note: the field can be left