The cooker switches off automatically if one or more
controls stay covered for more than 10 seconds.
To restore the proper operation:
- remove all objects from the control panel.
- clean the control panel.
- restart the cooker and the concerned area.
Overheating device
Before items of the cooker can overheat, the con-
trol reduces the used power by following this pro-
cedure for protection measures:
- Deactivation of booster and power booster if tur-
ned on.
- Reduction of the power level set.
- Shutdown of the cooking area concerned.
On the display of the cooking area the message
"E2" is displayed.
It is possible to restore the cooking area when the
default message is off.
ELECTRICAL SAFETY
The electrical system to which the cooker is
to be connected must be in accordance
with local standards and supplied with earthed
connection in compliance with safety regulations
in the country of use. It must also comply with Eu-
ropean standards regarding radio antistatic pro-
perties.
Make sure that it can't be possible to touch the power
cable of the cooker after it has been built-in and that
it is not subject to mechanical stress.
The socket used to connect the installed equipment
to the electrical power supply must be within reach:
otherwise, install a mains switch to disconnect the
hood when required.
Any changes to the electrical system must be carried
out by a qualified electrician.
Do not try to solve the problem yourself in the event
of equipment malfunction, but contact the Dealer or
an authorised Servicing Department for repairs.
When installing the cooker, disconnect the
equipment by removing the plug or swi-
tching off the main switch.
All manuals and user guides at all-guides.com
ELECTRICAL CONNECTION
(only intended for qualified personnel)
nected or cut:
in the event of damage, contact your nearest Servicing Department.
Refer to qualified personnel for electrical connections.
Connection must be carried out in compliance with the provisions of law
in force.
Before connecting the cooker to the mains power network, check that:
• the mains voltage corresponds with the voltage indicated on the data plate
• the electrical system is compliant and can withstand the load (see the techni-
• the power supply plug and cable do not come into contact with temperatu-
• the power supply system is effectively and properly connected to earth in
• the socket used to connect the cooker is within reach.
In case of:
• devices fitted with cables without a plug: the type of plug to use is a ''stan-
• fixed equipment not provided with a power supply cable and plug, or any
The yellow/green earth cable must not be cut off by the switch.
The Manufacturer declines all responsibility for failure to comply with the safety
regulations.
Connection of the cooker:
network
230V~
50/60Hz
* calculated with the contemporary factor in compliance with EN 60 335-2-6.
POWER:
Feature
Total power
Front position
Rated power
Booster power
Back position
Rated power
Booster power (1/2)
23
Disconnect the equipment from mains power network before car-
rying out any operation on the cooker.
Make sure that electric wires inside the cooker are not discon-
located inside the cooker;
cal specifications located inside the cooker);
res exceeding 70 °C;
compliance with regulations in force.
dardised'' one. The wires must be connected as follows: yellow-green for ear-
thing, blue for neutral and brown for the phase. The plug must be connected
to an adequate safety socket.
other device that ensures disconnection from the electrical mains, with an
opening gap of the contacts that enables total disconnection in overvoltage
category III conditions.
Said disconnection devices must be provided in the mains power supply in
compliance with installation regulations.
Cable
Connection
section
Single-phase
3 x 2.5 mm²
+ N
Switch
Power cable
gauge
H 05 VV - F
25 A *
H 05 RR - F
INDUCTION 2Z
3500W
1600W
1850W
2100W
2100/3000W