Cleaning
WARNING
Always wear safety goggles when cleaning tools with compressed air . The switches
must be kept clean and free of foreign matter. Do not attempt to clean by inserting pointed
objected through openings.
WARNING
ammonia and household detergents that contain ammonia.
Frequently blow out or vacuum any dust or metal chips that accumulate in and on the motor,
pulley housing, table, and work surface.
A coat of furniture paste wax applied to the table, column, and machined parts of the base will
help to keep these surfaces clean.
Storage
Store the tool indoors in a place that is inaccessible to children. Keep away from corrosive
agents.
TROUBLESHOOTING
Problem
1. Power cord is not plugged
2. Fuse or circuit breaker
Will not start
3. Cord damaged.
4. Burned out switch.
1. Extension cord too light or
Does not
2. Low house voltage.
come up to
speed
3. Tool may not function
The tool may be cleaned most effectively with compressed dry air.
Certain cleaning agents and solvents damage plastic parts. Some of
these are: gasoline, carbon tetrachloride, chlorinated cleaning solvents,
Cause
in.
tripped.
too long.
properly in cold
environment.
Remedy
1. Plug in the power cord.
2. Replace fuse or reset tripped circuit
breaker.
3. Have cord replaced by an Authorized Skil
Service Center or Service Station.
4. Have switch replaced by an Authorized
Skil Service Center or Service Station.
1. Replace with adequate cord.
2. Contact your electric company.
3. Tool functions best at room temperature.