DEKA Controls COM1/2
Temperaturbereiche / Temperature ranges / Plages
de température:
Medium / Medium / Fluide
Umgebung / Ambient / Environnement
Lagerung / storage / stockage
Luftfeuchtigkeit/Humidity/Humidité
Zeitverzögerung / Time delay / Temporisation
Alarm / alarme [sec]
Füllen / fill / remplissage [sec]
Alarmkontakt / alarm contact / Contact d'alarme
Schutzart / Protection class/Classe de protection
Rüttelfestigkeit (EN 60068-2-6)
Vibration resistance
Résistance aux vibrations
Medienverträglichkeit/Media compatibility /
Compatibilité des fluides
Ölanschluss/Oil connection/Raccord d'huile
CE-Konformität / CE mark / Marquage CE
Zulassungen / Approvals / Approbations
Weitere Informationen im Datenblatt
For more Information see data sheet
Plus d'informations sur la fiche technique
Lieferumfang
1 COM1/2 komplett
1 Einbauanleitung
Produktleistung
 Eigenständiges Regelgerät zur
Ölversorgung mit Ölstandsensor
und Magnetventil
 Präzise Ölstandmessung durch
Hall-Sensor.
 Keine Fehlmessungen durch auf-
schäumendes Öl oder Lichteinfall
 Mit LEDs für Alarm und Betriebs-
zustand.
Schutzart IP 65 mit angespritzten
Steckern und Leitungen
Funktionsbeschreibung
Das DEKA Controls COM1/2 ist ein
elektronisches Ölreguliersystem und
nimmt den Ölstand mittels eines Hall-
Sensors auf. Die Elektronik steuert
ein integriertes Magnetventil, sodass
bei Bedarf Öl von einem Sammler
kommend direkt in das Kurbelgehäu-
se des Kompressors fließt. Wenn der
notwendige Ölstand nicht erreicht
wird zeigt das DEKA Controls
COM1/2 einen Alarm an und der
Kontakt wechselt in die Alarmpositi-
on. Der Kontakt kann zur Alarmsig-
nalisierung oder auch zum Abschal-
ten des Kompressors verwendet
werden. DEKA Controls COM1/2 ist
für Kälteanlagen und Wärmepumpen
gem. EN 378 vorgesehen.
All manuals and user guides at all-guides.com
max. 3 A, 230 VAC potentialfrei / potential free / sans potentiel
Scope of delivery
1 complete COM1/2
1 Installation manual
Product highlights
 Self-contained unit for the
supply of oil with level sensor
and solenoid valve.
 Precise oil level measurement
based on Hall sensor.
 No incorrect measurements by
foaming oil or incidental light
 With LEDs for alarm and oper-
ating state.
 Protection class IP 65, electri-
cal connection with molded
plugs and cable
Description of function
The DEKA Controls COM1/2 is an
electronic oil management system
which uses a Hall sensor to
measure the oil level. The
integrated solenoid valve is
electronically controlled and is
used to feed oil directly into the
compressor sump, if required. If
the desired oil level is not reached
the DEKA Controls COM1/2
raises an alarm and the contact
switches to alarm position. The
contact can be used to signal an
alarm or shut down the
Compressor. DEKA Controls
COM1/2 is intended for
refrigeration systems and heat
pumps according to EN 378.
Seite/Page 3 - 8
-40 ... +80°C
-40... +50°C
-40 ... +80°C
0 – 80 % RH
90
10
IP65 (EN 60529)
4g, 10...250Hz
HFC, CO
HFKW,
2
R290, R1270
7/16"-20 UNF
Ja,yes,oui
Composition du kit
1 COM1/2 complète
1 Notice d'installation
Performances du produit
 Unité autonome pour la fourniture de
capteur de niveau d'huile et électro-
vanne.
 Mesure précise du niveau d'huile
grâce à un capteur à effet Hall.
 Aucune erreur de mesure due à
l'huile moussante ou l'incidence de la
lumière
 Avec LED pour alarme et état de
fonctionnement.
 Indice de protection IP 65 grâce à un
boitier scellé et un raccordement
électrique avec prises et câbles mou-
lés.
Description du fonctionnement
Le DEKA Controls COM1/2 est un sys-
tème électronique de régulation d'huile
qui mesure le niveau d'huile au moyen
d'un capteur à effet Hall. Le système
électronique pilote une électrovanne in-
tégrée de façon à ce que, selon le be-
soin, l'huile provenant d'un collecteur
coule directement dans le carter de vile-
brequin du Compresseur. Si le niveau
d'huile nécessaire n'est pas atteint le
DEKA Controls COM1/2 indique une
alarme et le contact mute en position
d'alarme. Le contact peut être utilisé
pour signaler l'alarme mais aussi pour
mettre hors tension le compresseur.
DEKA Controls COM1/2 est prévu pour
les installations de réfrigération et les
pompes à chaleur conformément à EN
378.