Télécharger Imprimer la page

Publicité

Liens rapides

Camille Bauer Metrawatt AG
Aargauerstrasse 7
CH-5610 Wohlen/Switzerland
Phone +41 56 618 21 11
Fax +41 56 618 21 21
info@cbmag.com
www.camillebauer.com
All manuals and user guides at all-guides.com
Programmieranleitung
KINAX N702-INOX HART über den HART Field
Communicator 475
Instructions de programmation
KINAX N702-INOX HART via HART Field Com-
municator 475
Programming Instructions
KINAX N702-INOX HART via the HART Field
Communicator 475
Istruzioni per la programmazione
KINAX N702-INOX HART via HART Field Com-
municator 475
N702-INOX HART
174 102-00
01.15

Publicité

loading

Sommaire des Matières pour Camille Bauer 475

  • Page 1 Istruzioni per la programmazione KINAX N702-INOX HART via HART Field Com- municator 475 N702-INOX HART 174 102-00 01.15 Camille Bauer Metrawatt AG Aargauerstrasse 7 CH-5610 Wohlen/Switzerland Phone +41 56 618 21 11 Fax +41 56 618 21 21 info@cbmag.com www.camillebauer.com...
  • Page 2 All manuals and user guides at all-guides.com...
  • Page 3 All manuals and user guides at all-guides.com Programmieranleitung KINAX N702-INOX HART über HART Field Communicator 475 Der KINAX N702-INOX HART lässt sich sehr einfach Sie befinden sich jetzt im Anzeigemodus über handelsübliche HART Field Communicator (z.B. Emerson Typ 475) programmieren.
  • Page 4 All manuals and user guides at all-guides.com 2. Programmierung Anwendungsfall 1: Wählen Sie Apply values Anfangs- und Endwert setzen Beim Anwendungsfall 1 befindet sich der Messbereich von 4 ... 20 mA zwischen zwei festen Winkelauslagen (z.B. 0° bis +60°) 2.2 Anfangswert setzen (45 Trim Loop Current Zero) Geber in Anfangsstellung bringen, dann 4 mA = 0% setzen (45 Trim Loop Current Zero [4 mA]) 2.1 Programmiermodus...
  • Page 5 All manuals and user guides at all-guides.com 3. Programmierung Anwendungsfall 2: 3.3 Messbereich setzen Nullpunkt setzen Wählen Sie Primary Variable Upper Range Value (PV URV) Beim Anwendungsfall 2 befindet sich der Messbereich von 4 ... 20 mA symmetrisch aufgeteilt zwischen zwei festen Winkelauslagen (z.B.
  • Page 6 All manuals and user guides at all-guides.com Instructions de programmation KINAX N702-INOX HART via HART Field Communicator 475 La programmation du KINAX N702-INOX HART est très Vous êtes maintenant en mode d‘affichage simple en utilisant des HART Field Communicator du commerce (p.
  • Page 7 All manuals and user guides at all-guides.com 2. Programmation Cas d’utilisation 1: Sélectionnez Apply values Les valeurs initiale et de finale Dans le cas d‘application n° 1, la plage de mesure de 4 ... 20 mA se situe entre deux butées angulaires fixes (p.ex. de 0°...
  • Page 8 All manuals and user guides at all-guides.com 3. Programmation Cas d’utilisation 2: 3.3 Mettre la plage de mesure Définir le point zéro Sélectionnez Primary Variable Upper Range Value (PV URV) Dans le cas d‘application n° 2, la plage de mesure de 4 ... 20 mA est subdivisée symétriquement entre deux butées angulaires fixes (p.ex.
  • Page 9 All manuals and user guides at all-guides.com Programming Instructions KINAX N702-INOX HART via the HART Field Communicator 475 KINAX N702-INOX HART may be very easily program- Your are now in the display mode med via commercially available HART field communi- cators (e.g.
  • Page 10 All manuals and user guides at all-guides.com 2. Programming use case 1: Select Apply values Set start and final value In application case 1, the measuring range of 4...20mA is between two firm angular positions (e.g. 0° to +60°) 2.2 Set start value (45 Trim Loop Current Zero) Put transmitter into initial position, set 4 mA = 0% (45 Trim Loop Current Zero [4 mA]) 2.1 Programming mode...
  • Page 11 All manuals and user guides at all-guides.com 3. Programming use case 2: 3.3 Set measuring range Set zero point Select Primary Variable Upper Range Value (PV URV) In application case 2, the measuring range of 4...20mA is symmetrically apportioned between two firm angular positions (e.g.
  • Page 12 All manuals and user guides at all-guides.com Istruzioni per la programmazione KINAX N702-INOX HART via HART Field Communicator 475 Il KINAX N702-INOX HART può essere programmato Adesso è attiva la modalità di visualizzazione molto facilmente con un comunicatore HART da campo (p. es.
  • Page 13 All manuals and user guides at all-guides.com 2. Programmazione caso applicativo 1: Selezionare Apply values Definire la posizione iniziale e quella finale Nel caso applicativo 1, il campo di misura 4 ... 20 mA si trova tra due angolazioni fisse (p. es. 0° ... +60°). 2.2 Definire la posizione iniziale (45 Trim Loop Current Zero) Portare il rilevatore nella posizione iniziale e impostare...
  • Page 14 All manuals and user guides at all-guides.com 3. Programmazione caso applicativol 2: 3.3 Campo di misura Definire lo zero Selezionare Primary Variable Upper Range Value (PV URV) Nel caso applicativo 2, il campo di misura 4 ... 20 mA è diviso simmetricamente tra due angolazioni fisse (p. es. -60°...
  • Page 15 All manuals and user guides at all-guides.com...