9.2 Cleaning and substituting the filters
When the vacuum cleaner deals with harmful substances for the operators health, the
substitution of the filters must be done wearing appropriate protective devices; operate if
possible in specific room. Moreover throw the filters in an appropriate plastic bag.
Remove the Lower Drum
Unscrew the nut that fixes the Filters' Protection
Remove the Filters' Protection
If the filter is damaged irreparably it is necessary to the substitute it.
Use only original spare parts: The use of cartridge filters non original could cause a lack of
the gasket grip or damages to the other devices (filter shaker).
In order to replace the filter unscrew the several nuts that fixes the filter; reassembling it make
sure that the filters' higher gasket fit together with the profile shaped by the cover.
Screw tight the 2 screws A and B showed in picture 3. Alternate screws while screwing them up
(Max 2 turn arounds). Doing that the ring seal won't get out of place.
10 T
V
HE
ACUUM
If the Vacuum Cleaner is malfuctioning follow the steps below:
10.1
Check the ring seal's filters
After you removed the filter's protection, check the right tighting of screws A and B (photo 3).
(2 turns for screw A and 2 for screw B repite this sequence untill the screws are tight).
A
B
Photo 3 –
Check the right
tighting of screws A and B.
10.2. Cleansing cycle of the filters (Only M
1. Turn on the exhaust fan
2. Pull out the extractor pipe from the pipe union (K) and cover it
with a hand. At the same time act on the valve lever (L) for at
least 60 sec. in order to start the filter cleansing.
3. Repeat operation n. 2 on all valves!!!