WRONG SETTING
Saturation (Bubbles in the reactor): If you enter too
much CO2, the CO2 concentration in the water will be
too high for other CO2 to dissolve. Immediately lower
the CO2 intake.
Precipitation (White water in the reactor): If the PH is
too low for the used media, the dissolved material
may precipitate causing component wear.
Immediately lower the CO2 intake
MAINTENANCE
Before performing any maintenance, disconnect the
product from power supply. Do not use abrasive
products, toxic and unsuitable for cleaning operation.
Every day: Check every day for leaks and cracks. Check
correct CO2 input through the bubble counter and
check the water out flow.
Every 7 days: Measure the output flow and check KH°
value, in the case correct the CO2 input flow. Check
values in the tank, in case correct them buffer with
liquid or powder. Check if the drain valve is not clogged
or covered with debris. In case replace it with a new
one.
Warning: The metal components may be subject to
surface oxidation, clean every sign of oxidation.
Every 120 days: Perform complete control by removing
the reactor from the sump and taking it apart.
Completely replace the medium inside the reactor.