8

Troubleshooting

Function
Input low-
voltage alarm
Input low-
voltage
shutdown
Input over-
voltage
shutdown
Overload
shutdown
Over temperature
shutdown
Output short
circuit
Status description
LED
Alarm
green on
yes
red off
green on
yes
red on
green on
no
red on
green on
no
red on
green on
yes
red on
green on
no
red on
Method for restart
AC-
output
When the battery is back
yes
to normal voltage, the
alarm automatically stops�
• Charge the battery�
• Switch off the voltage
no
converter for 3-5 seconds
• Switch the voltage con-
verter on again�
• Check the battery for
correct voltage or re-
store it�
no
• Switch off the voltage
converter for 3-5 seconds�
• Switch the voltage con-
verter on again�
• Reduce the load to the
specified continuous load.
• Switch off the voltage
no
converter for 3-5 seconds�
• Switch the voltage con-
verter on again�
• Eliminate the cause of
overheating�
• Switch off voltage con-
no
verter for ~5 minutes to
cool down�
• Switch the voltage con-
verter on again�
• Eliminate the cause of
the short circuit�
no
The voltage transformer
then continues to operate
automatically�
EN
18