InstallatIon
General information
1. General information
this document is intended for contractors.
Note
Read these instructions carefully before using the ap-
pliance and retain them for future reference.
Pass on the instructions to a new user if required.
1.1
Relevant documents
Heat pump operating and installation instructions
Note
Please see appliance operating and installation in-
structions for information on the "Guarantee" and
"Environment and recycling".
1.2 Units of measurement
Note
all measurements are given in mm unless stated oth-
erwise.
2. Appliance description
Dimensions
462
410
2.1
Standard delivery
- 4 screws M8x30
- 4 washers
4 |
All manuals and user guides at all-guides.com
3. Preparations
3.1
1 air intake side
2 air discharge side
3 Main wind direction
Heat pump
3.5 aCs, 07 aCs classic
4.5 aCs, 09 aCs classic
8.5 aCs, 17 aCs classic
f Erect a strip foundation at the heat pump installation site.
f
3.2 Gravel bed
1 Drainage pipe
Heat pump
3.5 aCs, 07 aCs classic
4.5 aCs, 09 aCs classic
8.5 aCs, 17 aCs classic
f lay a drainage pipe under the appliance to drain moisture
f
f Create a sufficiently sized gravel bed within the strip
f
Foundation
3
150
A
865
865
995
a
700
700
830
away from the building.
foundation.
1
A
150
2
B
C
500
418
500
418
500
418
a
1
sK 2