Installation Instructions
EN
Electrical supply
Before installing the oven have a qualified electrician verify that your
home is provided with adequate electrical service and that the addition
of the oven will not overload the branch circuit on which it is to be
installed.
A separate three-wire or four-wire single phase, 120/240 Volt, 60
Hz, or a 120/208 Volt, 60Hz branch circuit is required.
NOTE: For use with 120/208 v, 60 hz supply voltage, see
connecting to 208 volt circuit.
For hook-up of the oven you will need to have an approved junction
box installed where it will be easily reached through the front of the
cabinet where the oven will be located. The oven has 3 feet of conduit.
Allow two to three feet of slack in the line so that the oven can be moved
if servicing is ever necessary.
DO NOT shorten the flexible conduit.
LOCATION OF RATING PLATE
Wiring requirements
When making the wire connections, use the entire length of the conduit
provided (3 feet). The conduit must not be cut.
Before making connections make sure the power is off and read and
observe the following:
1. A separate three-wire or four-wire, single phase, 120V/240V, 60
Hz or 120V/208V, 60 Hz branch circuit is required for the oven.
2. The oven must be connected with Copper or Aluminum wire.
3. In the United States:
Wiring must conform to the National Electrical Code, ANSI/
NFPA No. 70 latest edition. You can obtain a copy of the National
Electrical Code by writing to: National Fire Protection Association
Batterymarch Park Quincy, MA 02269
6
In Canada:
Wiring must conform to Canadian Electrical Code C22.1- latest
edition. You can obtain a copy of the Canadian Electrical Code by
writing to: Canadian Standards Association 178 Rexdale Boulevard
Rexdale (Toronto), Ontario, Canada M9W 1R3
4. Wire size (Copper or Aluminum wire) and connections must be
suitable for the rating of the appliance as per the National Electrical
Code requirements. The flexible armoured cable extending from the
oven should be connected directly to the junction box.
5. The junction box should be located so as to allow as much slack as
possible between the junction box and the oven so it can be moved
if servicing is ever required.
6. A U.L. listed conduit connector must be provided at each end of the
power supply cable.
WARNING
ELECTRICAL SHOCK HAZARD
• The electrical power to the oven branch circuit must be shut off
while line connections are being made.
• Do not use an extension cord with this appliance.
• Electrical ground is required on this appliance. The free end of
the green wire (the ground wire) must be connected to a suitable
ground. This wire must remain grounded to the oven.
• If cold water pipe is interrupted by plastic, non metallic gaskets,
union connections or other insulating materials, DO NOT use for
grounding.
• DO NOT ground to a gas pipe.
• DO NOT have a fuse in the NEUTRAL or GROUNDING circuit.
A fuse in the NEUTRAL or GROUNDING circuit could result in an
electrical shock.
• Check with a qualified electrician if you are in doubt as to whether
the appliance is properly grounded.
• Failure to follow these instructions could result in serious injury or
death.
CAUTION
Do not repair or replace any part of the appliance unless specifically
recommended in the manual. All other servicing should be done by
a qualified technician. This may reduce the risk of personal injury and
damage to the oven.
Never modify or alter the construction of the appliance by removing
panels, wire covers, screws, or any other part of the product.