Télécharger Imprimer la page

Symmons Temptrol 262XBODY Manuel D'installation

Publicité

Liens rapides

262XBODY & 162XBODY
PRESSURE-BALANCING SHOWER & TUB/
SHOWER VALVE BODY
SPECIFICATION SUBMITTAL
Model Numbers
262XBODY
Pressure-balancing tub/shower
valve body with service stops
162XBODY
Pressure-balancing tub/shower
valve body with pressure testing
cap and service stops
Options/Modifications
RV
Reverse seat
BR
Temptrol Rapid Install™ Bracket
CHKS
Integral check stops for use in
installations where a positive
shutoff device is used downstream of
valve
CP
CPVC fittings
P1
PEX crimp fittings
P2
PEX expansion fittings
P3
ProPress® fittings
TD
Tub drop
SKU Builder
Reverse
Series
Seat
262X
RV
262X
Architectural/Engineering Specification
Symmons __________ PRESSURE-BALANCING SHOWER & TUB/ SHOWER VALVE BODY. Includes brass, bronze, and stainless steel
construction, pressure-balancing mixing valve to maintain safe shower temperature, adjustable stop screw to control maximum hot
water temperature to valve, integral service stops enable water shutoff for valve servicing, and 4-port valve body in common plane.
Inlets: 1/2" IPS and 1/2" sweat. Outlets: 1/2" IPS and 1/2" sweat. Optional reverse seat. Accommodates thin wall installations. Stringer
mounts included. 10-Year Commercial Warranty. ASME A112.18.1/CSA B125.1, ASSE 1016, and Buy American Act compliant. Available
options: RV = Reverse seat, BR = Temptrol Rapid Install Bracket, CHKS = Integral check stops for use in installations where a positive
shutoff device is used downstream of valve, CP = CPVC fittings, P1 = PEX crimp fittings, P2 = PEX expansion fittings, P3 = ProPress
fittings, and TD = Tub drop.
Symmons Industries, Inc.
Copyright © 2024 Symmons Industries, Inc.
Temptrol
Location:
Check
Fit-
Stops
tings
CHKS
P1
P2
31 Brooks Drive
Braintree, MA 02184
symmons.com
®
Feature Highlights
Brass, bronze, and stainless steel construction.
Pressure-balancing mixing valve to maintain safe
shower temperature.
Adjustable stop screw to limit handle rotation.
Integral service stops enable water shutoff for valve
servicing.
4-port valve body in common plane.
Inlets: 1/2" IPS and 1/2" sweat.
Outlets: 1/2" IPS and 1/2" sweat.
Optional reverse seat.
Accommodates thin-wall installations.
Stringer mounts included.
Warranty
Limited Lifetime - for residential
installations.
10 Years - for commercial/industrial
installations.
Refer to www.symmons.com/warran-
ty for complete warranty information.
Compliance
ASME® A112.18.1/CSA® B125.1
ASSE 1016
Buy American Act Compliant
Rapid
Tub
BODY
Install
Drop
BR
BODY
BR
TD
BODY
Phone: (800) 796-6667
gethelp@symmons.com
262XBODY
Final SKU
262XRVCHKSP1BRBODY
262XP2BRTDBODY
Fax: (800) 961-9621
ZV-3865 REV A
091224
162XBODY

Publicité

loading

Sommaire des Matières pour Symmons Temptrol 262XBODY

  • Page 1 262XP2BRTDBODY Architectural/Engineering Specification Symmons __________ PRESSURE-BALANCING SHOWER & TUB/ SHOWER VALVE BODY. Includes brass, bronze, and stainless steel construction, pressure-balancing mixing valve to maintain safe shower temperature, adjustable stop screw to control maximum hot water temperature to valve, integral service stops enable water shutoff for valve servicing, and 4-port valve body in common plane.
  • Page 2 P/N 262XP2BODY P/N 262XP3BODY P/N 262XP3BODY ■ ■ ■ ■ Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 Fax: (800) 961-9621 ■ ■ ■ ■ Copyright © 2024 Symmons Industries, Inc. symmons.com gethelp@symmons.com ZV-3865 REV A 091224...
  • Page 3 *Bracket straps can be cut or bent to installation requirements ■ ■ ■ ■ Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 Fax: (800) 961-9621 ■ ■ ■ ■ Copyright © 2024 Symmons Industries, Inc. symmons.com gethelp@symmons.com ZV-3865 REV A 091224...
  • Page 4 Spécification architecturale/technique Symmons __________ CORPS DE VANNE DE DOUCHE ET DE BAIGNOIRE À PRESSION ÉQUILIBRÉE. Comprend une construction en laiton, en bronze et en acier inoxydable, un mitigeur à équilibrage de pression pour maintenir une température de douche sûre, une vis d'arrêt réglable pour contrôler la température maximale de l'eau chaude de la vanne, des arrêts de service intégrés permettent de couper l'eau pour l'entretien de la vanne et un corps...
  • Page 5 P/N 262XP2BODY P/N 262XP3BODY P/N 262XP3BODY ■ ■ ■ ■ Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 Fax: (800) 961-9621 ■ ■ ■ ■ Copyright © 2024 Symmons Industries, Inc. symmons.com gethelp@symmons.com ZV-3865 REV A 091224...
  • Page 6 *Les sangles de support peuvent être coupées ou pliées selon les exigences d'installation ■ ■ ■ ■ Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 Fax: (800) 961-9621 ■ ■ ■ ■ Copyright © 2024 Symmons Industries, Inc. symmons.com gethelp@symmons.com ZV-3865 REV A 091224...

Ce manuel est également adapté pour:

Temptrol 162xbody