14. Burner adjustment
Please note: To set the system to stop the baffle plate (1), loosen the screw (3). To set the
electrode system, loosen the screw (4).
Heating
Device
output
K 160
eco-e
161 kW
Pump
Nozzle
pressure
3.25 Gph
60° B
1st level 9.0 bar
Delavan
2nd level 13.0 bar
Item No.
1630005
Burner
Air valve
head
setting
setting
1st level 0.9
4
2nd level 3.25
49
Burner type
RG 3D TC
EN

Publicité

loading

Produits Connexes pour Heylo K Serie

Ce manuel est également adapté pour:

K 160 eco-e1101672