Safety instructions

DANGER!
Personal danger due to electric shock or
burns!
Assembly and electrical connections must com-
ply with the national regulations.
Assembly, installation, upgrading, maintenance
or repair of the unit may only be carried out by
specially trained and instructed personnel.
– Disconnect the device from the power supply
before performing any work.
DANGER!
Risk of eye and skin damage due to UV-C ra-
diation!
Even when radiation periods are short, UV-C ra-
diation can severely damage the skin and eyes!
Direct irradiation of eyes and skin must be strictly
avoided.
– Disconnect the device from the power supply
before carrying out any maintenance work
and before opening the unit.
– Never operate UV-C lamps outside the device
or when it is open!
DANGER!
Risk of eye and skin damage due to UV-C ra-
diation!
Connection to the mains can be made before as
well as after installation. It is imperative that the
power supply is switched off during assembly so
that the unit cannot be turned on by mistake and
UV-C radiation cannot escape.
– Switch off the power supply before the as-
sembly and back on only after the assembly
work has been fully completed.
CAUTION!
To protect the unit from unauthorised opening
and to secure the guarantee claims, all brackets
must be sealed!
CAUTION!
Using unsuitable lamps can eliminate the
effectiveness of the unit and void the CE
conformity!
– Use genuine UV-C lamps only.
1) In Germany: VDE regulations
1)

General safety instructions

– Unauthorised changes to the unit are prohibited. The
manufacturer shall bear no liability for damage or inju-
ries resulting from such actions.
– The brackets are sealed to prevent unauthorised open-
ing. Brackets that do not have a seal or brackets with a
damaged seal may lead to a hazard to the user and
lead to the loss of the manufacturers guarantee.
– The device is only to be used if it is working correctly!
– No safety equipment (e.g. stickers, seals, protective
cover or other components/attached parts) may be re-
moved or deactivated which could impair the safe op-
eration of the unit!
– If it is obvious that the unit is damaged, it must not be
put into operation!
– Air intake and air outlet openings should not be cov-
ered!
CAUTION!
Risk of damage to the device!
UV-C lamps are sensitive components and may
be easily damaged.
– Do not touch the lamps with bare hands..
Wear protective gloves.
– Take care when touching and installing the
lamps. Do not bend the lamps. Do not rest the
lamps on the pins.
CAUTION!
Only use genuine spare parts of the same
model! Using other spare parts can eliminate the
effectiveness of the unit and void the CE con-
formity!
Any liability is excluded in case of damage or
injury proven to be the result of the use of non-
genuine spare parts.
Operating instructions - 5/30